Air source heat pumps, surveyed, designed and installed· Free home survey for installation enquiries
0800 088 6341
Air source heat pump installation
Greater London · E10

Air source heat pump installation in Leyton

Air source heat pump installation for homes in Leyton, designed from a room-by-room heat loss survey and installed by installers working under our contract. The price is fixed in a written quote before anything is ordered.

Area
Greater London
Postcode district
E10
Nation
England
Guide price
From £10,650 inc VAT
Survey
Free for installation enquiries

Before you book: air source heat pump installation in Leyton

The question for a Leyton home is rarely whether a heat pump can work, but what needs to change to make it work well: radiator sizes, pipework, controls and where the unit goes.

In Leyton, cylinder space is planned with you, often in an airing cupboard, utility room or garage. Homeowners across Greater London can arrange a survey in Leyton for a room-by-room design and a written quote before committing to anything.

We survey your home, design a heat pump system around its real heat loss, and manage the installation from the first visit to the MCS certificate.

  • Households with room for a hot water cylinder
  • Homes replacing a gas, oil, LPG or electric heating system
  • Houses with reasonable insulation, or a plan to improve it

What's included

  • Commissioning, handover and a walk-through of the controls
  • MCS registration and certificate, plus network operator notification
  • Free home survey and room-by-room heat loss calculation
  • Radiator and pipework changes where the design needs them
  • Boiler Upgrade Scheme application in England and Wales where eligible

Installers working in Leyton plan the order of work so heating and hot water are off for as short a time as practical.

Grants and rules for heat pumps in England

England

Homes in Leyton can use the Boiler Upgrade Scheme, which takes £7,500 off the cost of an air source heat pump when it replaces fossil-fuel or electric heating. Replacing oil or LPG heating qualifies for £9,000 for installations from 21 July 2026 to 31 March 2027, and air-to-air systems for £2,500. The MCS-certified installer named in your quote applies for the grant and deducts it from the price.

There is no VAT on installing a heat pump anywhere in the UK until 31 March 2027. In England most houses can have an air source heat pump under permitted development, provided the unit meets the MCS noise and siting standards; the old 1 m boundary limit was removed on 29 May 2025. We flag listed buildings, flats and sensitive conservation-area positions at survey.

Air source heat pump installation prices in Leyton

Here are typical prices for air source heat pump installation in Greater London, installed and including VAT. Use the guide price tool for a figure based on your home, then a survey confirms it in writing.

Air source heat pump installation prices in Leyton
HomeTypical sizeInstalled guide priceAfter £7,500 grant
1–2 bedroom flat or small terrace4–5 kW£10,650–£14,000£3,150–£6,500
2–3 bedroom terrace or semi5–7 kW£11,750–£15,100£4,250–£7,600
3 bedroom semi or small detached6–9 kW£13,450–£17,350£5,950–£9,850
4 bedroom detached8–12 kW£15,700–£20,150£8,200–£12,650
5+ bedroom or larger older house11–16 kW£18,500–£25,200£11,000–£17,700

Installed, inc VAT: unit, cylinder, controls, minor pipework and commissioning.

Designing for Leyton's winters

7 h 49 minDaylight on the shortest day
16 h 39 minDaylight on the longest day
15°Noon sun height in December
51.57°NLatitude of Leyton

On the shortest day Leyton gets about 7 hours 49 minutes of daylight, and the winter sun reaches only around 15° above the horizon at noon. Winters this far south are milder than in most of the UK, which helps a heat pump run at low flow temperatures for much of the season.

What happens after you enquire in Leyton?

  1. Start online with a guide price or call us.
  2. A home survey in Leyton gives us the room-by-room heat loss.
  3. Your written quote sets out the design, the price and the grant position where you live.
  4. Installation is booked for dates that suit you; most homes take 2–4 days on site.
  5. After commissioning you get a handover of the controls and settings, plus the certificates.

Air source heat pump installation in Leyton: questions

How long does a heat pump survey take in Leyton?

A home survey in Leyton usually takes one to two hours. The surveyor measures every heated room, checks windows, walls and radiators, and looks at where the outdoor unit and cylinder can go.

Do you cover Walthamstow as well as Leyton?

Yes. We arrange surveys and installation in Walthamstow, which is about a mile north of Leyton, and across Greater London.

What size heat pump does a Leyton home need?

It depends on the heat loss, not the postcode. As a rough guide, a 3 bedroom semi often needs 6–9 kW, but the room-by-room survey sets the actual size for your Leyton home.

Do I need new radiators for a heat pump?

Not always; many homes keep most of their radiators and change only a few. Because a heat pump runs at a lower water temperature than a boiler, each radiator gives out less heat, so the survey checks every room against its heat loss. Rooms where the existing radiator falls short get a larger one, with a guide price of £250–£450 each, installed and including VAT.

Will an air source heat pump be noisy?

Heat pumps are designed to run quietly, but where the unit sits makes a real difference. The survey looks for a position away from bedroom windows and neighbours, with clear airflow, and the installation must pass the MCS noise assessment. The fan is most noticeable on very cold days when the unit works hardest, and a little vapour during the periodic defrost is normal.

Ready to price your heat pump?

Use the guide price tool, or book a free home survey and fixed written quote.

CallGet a quote