Air source heat pumps, surveyed, designed and installed· Free home survey for installation enquiries
0800 088 6341
Air-to-air heat pumps
Greater London · N16

Air-to-air heat pumps in Stoke Newington

Homeowners in Stoke Newington can get a guide price for air-to-air heat pumps in a couple of minutes, then book a survey. The design covers the outdoor unit position, radiators and hot water, not just the box outside.

Area
Greater London
Postcode district
N16
Nation
England
Guide price
From £2,700 inc VAT
Survey
Free for installation enquiries

Air-to-air heat pumps for Stoke Newington homes

Homes around Stoke Newington range from older terraces to newer estates, and each needs a different design. That is why we survey before we quote.

Installers in Stoke Newington plan condensate drains and pipe covers so indoor and outdoor runs stay neat. Flats in Stoke Newington on storage or panel heaters can often switch to air-to-air without fitting radiators or pipework.

An air-to-air heat pump warms rooms directly with air, and can cool them in summer, but it does not heat your hot water.

  • Rooms that get too hot in summer as well as cold in winter
  • Households that already have, or will add, a separate source of hot water
  • Homes where fitting radiators and pipework would be very disruptive

What's included

  • Commissioning, MCS certificate and the air-to-air grant claim in England and Wales where eligible
  • Refrigerant pipe runs to each indoor unit, made and charged by an F-gas certified engineer
  • Condensate drains and neat external pipe covers
  • Electrical supply and controls set up for each room
  • Outdoor unit and indoor units for each room

For terraced homes in Stoke Newington, the outdoor unit can often sit in a rear yard with tidy pipe runs to each room.

Grants and rules for heat pumps in England

England

Homes in Stoke Newington can use the Boiler Upgrade Scheme, which takes £7,500 off the cost of an air source heat pump when it replaces fossil-fuel or electric heating. Replacing oil or LPG heating qualifies for £9,000 for installations from 21 July 2026 to 31 March 2027, and air-to-air systems for £2,500. The MCS-certified installer named in your quote applies for the grant and deducts it from the price.

There is no VAT on installing a heat pump anywhere in the UK until 31 March 2027. In England most houses can have an air source heat pump under permitted development, provided the unit meets the MCS noise and siting standards; the old 1 m boundary limit was removed on 29 May 2025. We flag listed buildings, flats and sensitive conservation-area positions at survey.

Air-to-air heat pumps prices in Stoke Newington

Guide prices for Stoke Newington and the rest of Greater London are shown below, installed and inc VAT. We publish ranges rather than a single figure because design details move the price, and the written quote after survey fixes it.

Air-to-air heat pumps prices in Stoke Newington
SystemInstalled guide price
Air-to-air heat pump, 1–2 rooms£2,700–£5,600
Air-to-air heat pump, multi-room 3–4 bedroom home£4,500–£8,950

Installed, inc VAT. Air-to-air systems heat (and can cool) rooms but do not provide hot water. In England and Wales the Boiler Upgrade Scheme gives £2,500 towards an air-to-air system in a home, deducted from your quote where eligible.

Winter daylight and heating in Stoke Newington

7 h 49 minDaylight on the shortest day
16 h 39 minDaylight on the longest day
15°Noon sun height in December
51.56°NLatitude of Stoke Newington

On the shortest day Stoke Newington gets about 7 hours 49 minutes of daylight, and the winter sun reaches only around 15° above the horizon at noon. Winters this far south are milder than in most of the UK, which helps a heat pump run at low flow temperatures for much of the season.

What happens after you enquire in Stoke Newington?

  1. Start online with a guide price or call us.
  2. A home survey in Stoke Newington gives us the room-by-room heat loss.
  3. Your written quote sets out the design, the price and the grant position where you live.
  4. Installation is booked for dates that suit you; most homes take 2–4 days on site.
  5. After commissioning you get a handover of the controls and settings, plus the certificates.

Air-to-air heat pumps in Stoke Newington: questions

Do you cover Highbury as well as Stoke Newington?

Yes. We arrange surveys and installation in Highbury, which is about a mile south-west of Stoke Newington, and across Greater London.

How long does a heat pump survey take in Stoke Newington?

A home survey in Stoke Newington usually takes one to two hours. The surveyor measures every heated room, checks windows, walls and radiators, and looks at where the outdoor unit and cylinder can go.

Do I need new radiators for a heat pump in Stoke Newington?

Often some, not all. Heat pumps run best at lower water temperatures, so rooms with small radiators may need larger ones. The survey of your Stoke Newington home gives a room-by-room list.

Is there a grant for air-to-air heat pumps?

In England and Wales, yes: the Boiler Upgrade Scheme includes a grant of £2,500 for air-to-air heat pumps in homes, from 28 April 2026. The MCS-certified installer applies to Ofgem and deducts it from your quote, subject to the scheme's conditions. The scheme does not cover Scotland or Northern Ireland; in Scotland, Home Energy Scotland has its own rules.

How much sound do the indoor units make?

Indoor units are designed to run quietly, with a fan you will hear most when heating or cooling at full output. Lower fan settings and night modes reduce sound in bedrooms. Siting matters for the outdoor unit too: it needs airflow and a position that passes the MCS noise assessment. Ask to see the sound levels of the proposed units at survey.

Ready to price your heat pump?

Use the guide price tool, or book a free home survey and fixed written quote.

CallGet a quote