- Area
- Cornwall
- Postcode district
- PL12
- Nation
- England
- Guide price
- Priced after survey
- Survey
- Free for installation enquiries
What to know about heat loss surveys in Saltash
The question for a Saltash home is rarely whether a heat pump can work, but what needs to change to make it work well: radiator sizes, pipework, controls and where the unit goes.
Homeowners in Saltash thinking about insulation work can use the survey to see how it would change their heat pump size. Houses in Saltash built in different eras can need very different heat pump sizes, which is why each is calculated room by room.
Every heat pump we quote starts with a room-by-room heat loss survey, free with installation enquiries and also available as a stand-alone report.
- Homeowners planning insulation or building work who want to know the effect on heat demand
- Self-builders and architects who need emitter and system sizes early
- Anyone getting a heat pump quote, as the first step
What's included
- Room-by-room heat loss calculation using the MCS method
- Radiator schedule with any upgrades needed for each room
- Recommended heat pump size and design flow temperature
- Electrical supply and network operator notes
- Outdoor unit siting options and noise check
A surveyor visits your Saltash home to measure each room, window and wall before any heat pump is sized.
Grants and rules for heat pumps in England
In England the Boiler Upgrade Scheme gives £7,500 towards an air source heat pump (£9,000 if it replaces oil or LPG, from 21 July 2026 to 31 March 2027), and since 28 April 2026 a valid EPC is no longer needed. The grant is applied for by the MCS-certified installer and shown as a deduction on your Saltash quote.
There is no VAT on installing a heat pump anywhere in the UK until 31 March 2027. In England most houses can have an air source heat pump under permitted development, provided the unit meets the MCS noise and siting standards; the old 1 m boundary limit was removed on 29 May 2025. We flag listed buildings, flats and sensitive conservation-area positions at survey.
Guide prices for heat loss surveys in Saltash
These are guide prices for Cornwall, installed and including VAT. Your final price is fixed in a written quote after the survey and depends on the heat loss of the house, the radiators that need changing and where the unit goes.
| Survey | Guide price |
|---|---|
| Home survey and heat loss calculation with an installation quote | Free |
| Stand-alone heat loss survey and report | £150–£410 |
Inc VAT. A stand-alone report is for homeowners who want the design without an installation quote.
Winter daylight and heating in Saltash
Saltash sees roughly 8 hours 00 minutes of daylight in late December against 16 hours 26 minutes in June. Milder southern winters suit heat pumps well, though the system is still sized for a cold snap rather than an average day.
From survey to switch-on in Saltash
- Send your postcode and a few details, or use the guide price tool.
- A surveyor visits your Saltash home, measures every room and checks where the outdoor unit can go.
- You receive a heat loss design and a fixed written quote, with any grant shown where it applies.
- Installers fit the unit, cylinder and any radiator changes, typically over 2–4 days on site.
- The system is commissioned, set up with weather compensation and handed over with the paperwork.
Heat loss surveys in Saltash: questions
How long does installation take in Saltash?
Most installations take 2–4 days on site. Jobs with several radiator changes or new pipework take longer, and your quote for a Saltash home states the expected time.
Do I need new radiators for a heat pump in Saltash?
Often some, not all. Heat pumps run best at lower water temperatures, so rooms with small radiators may need larger ones. The survey of your Saltash home gives a room-by-room list.
Where would the outdoor unit go on a Saltash house?
Usually at the side or rear, on a level base with space around it for airflow and servicing, away from bedroom windows where possible. The surveyor checks positions at your Saltash home.
Will the survey check noise from the outdoor unit?
Yes. The surveyor identifies possible positions for the outdoor unit and carries out the MCS noise assessment, which estimates the sound level at the nearest neighbouring window from the unit's sound power level, distance and any barriers. In England, meeting the MCS planning standards is one of the conditions for permitted development. Wales, Scotland and Northern Ireland have their own rules, which we check.
What is a design flow temperature?
The design flow temperature is the temperature of the water sent to your radiators or underfloor heating on the coldest design day. Heat pumps are more efficient at lower flow temperatures, typically around 35–50°C. Choosing it is a balance: a lower figure improves efficiency but can mean larger radiators in some rooms, so the design shows both.

