Air source heat pumps, surveyed, designed and installed· Free home survey for installation enquiries
0800 088 6341
Heat loss survey
Derbyshire · NG10

Heat loss survey in Long Eaton

We cover Long Eaton and the surrounding Derbyshire area for heat loss surveys, with installation carried out by installers we appoint and manage under one contract.

Area
Derbyshire
Postcode district
NG10
Nation
England
Guide price
Priced after survey
Survey
Free for installation enquiries

Heat loss survey in Long Eaton: what to expect

Every property in Long Eaton is different, so the design starts from measurements rather than a rule of thumb. That keeps the system the right size and the running costs predictable.

Design outdoor temperatures for Long Eaton and the wider Derbyshire come from local cold-weather data, not a national average. Homeowners in Long Eaton thinking about insulation work can use the survey to see how it would change their heat pump size.

Every heat pump we quote starts with a room-by-room heat loss survey, free with installation enquiries and also available as a stand-alone report.

  • Homes with an existing heat pump that seems undersized or expensive to run
  • Landlords comparing properties before deciding where to switch first
  • Self-builders and architects who need emitter and system sizes early

What's included

  • Hot water cylinder sizing for your household
  • Written results in your quote, or a stand-alone report if you order one
  • Electrical supply and network operator notes
  • Outdoor unit siting options and noise check
  • Recommended heat pump size and design flow temperature

The survey in Long Eaton includes a check of where the outdoor unit could sit and how its sound would reach neighbours.

Grants and rules for heat pumps in England

England

In England the Boiler Upgrade Scheme gives £7,500 towards an air source heat pump (£9,000 if it replaces oil or LPG, from 21 July 2026 to 31 March 2027), and since 28 April 2026 a valid EPC is no longer needed. The grant is applied for by the MCS-certified installer and shown as a deduction on your Long Eaton quote.

There is no VAT on installing a heat pump anywhere in the UK until 31 March 2027. In England most houses can have an air source heat pump under permitted development, provided the unit meets the MCS noise and siting standards; the old 1 m boundary limit was removed on 29 May 2025. We flag listed buildings, flats and sensitive conservation-area positions at survey.

Heat loss survey prices in Long Eaton

Guide prices for Long Eaton and the rest of Derbyshire are shown below, installed and inc VAT. We publish ranges rather than a single figure because design details move the price, and the written quote after survey fixes it.

Heat loss survey prices in Long Eaton
SurveyGuide price
Home survey and heat loss calculation with an installation quoteFree
Stand-alone heat loss survey and report£150–£400

Inc VAT. A stand-alone report is for homeowners who want the design without an installation quote.

Designing for Long Eaton's winters

7 h 35 minDaylight on the shortest day
16 h 55 minDaylight on the longest day
14°Noon sun height in December
52.90°NLatitude of Long Eaton

On the shortest day Long Eaton gets about 7 hours 35 minutes of daylight, with the noon sun around 14° up. The heating season runs from autumn into spring, so a heat pump that is sized correctly and set up with weather compensation does most of its work in steady, cool conditions.

What happens after you enquire in Long Eaton?

  1. Start online with a guide price or call us.
  2. A home survey in Long Eaton gives us the room-by-room heat loss.
  3. Your written quote sets out the design, the price and the grant position where you live.
  4. Installation is booked for dates that suit you; most homes take 2–4 days on site.
  5. After commissioning you get a handover of the controls and settings, plus the certificates.

Heat loss surveys in Long Eaton: questions

Do I need new radiators for a heat pump in Long Eaton?

Often some, not all. Heat pumps run best at lower water temperatures, so rooms with small radiators may need larger ones. The survey of your Long Eaton home gives a room-by-room list.

Where would the outdoor unit go on a Long Eaton house?

Usually at the side or rear, on a level base with space around it for airflow and servicing, away from bedroom windows where possible. The surveyor checks positions at your Long Eaton home.

Can you service a heat pump in Long Eaton that someone else installed?

Yes. We arrange servicing and repairs for most air source heat pumps in Long Eaton, whoever fitted them. Tell us the make and model when you book.

Will the survey check noise from the outdoor unit?

Yes. The surveyor identifies possible positions for the outdoor unit and carries out the MCS noise assessment, which estimates the sound level at the nearest neighbouring window from the unit's sound power level, distance and any barriers. In England, meeting the MCS planning standards is one of the conditions for permitted development. Wales, Scotland and Northern Ireland have their own rules, which we check.

Why can't you size the heat pump from my boiler?

Boilers are often much larger than a home's real heat loss, because they are sized for fast hot water and quick warm-ups. Matching a heat pump to the boiler's output usually means an oversized unit that costs more and switches on and off too often. A room-by-room calculation finds the actual heat demand, which is what the heat pump needs to meet.

Ready to price your heat pump?

Use the guide price tool, or book a free home survey and fixed written quote.

CallGet a quote