Air source heat pumps, surveyed, designed and installed· Free home survey for installation enquiries
0800 088 6341
Heat loss survey
Greater London · SM1

Heat loss survey in Sutton

We cover Sutton and the wider SM1 district for heat loss surveys. Start with a guide price online, then a free home survey for installation enquiries confirms the design.

Area
Greater London
Postcode district
SM1
Nation
England
Guide price
Priced after survey
Survey
Free for installation enquiries

Heat loss survey for Sutton homes

Most homes can run on a heat pump if the system is designed properly, and Sutton is no different. The key is matching the heat pump and radiators to the home's heat loss.

Design outdoor temperatures for Sutton and the wider Greater London come from local cold-weather data, not a national average. Homeowners in Sutton thinking about insulation work can use the survey to see how it would change their heat pump size.

Every heat pump we quote starts with a room-by-room heat loss survey, free with installation enquiries and also available as a stand-alone report.

  • Homes with an existing heat pump that seems undersized or expensive to run
  • Homeowners planning insulation or building work who want to know the effect on heat demand
  • Landlords comparing properties before deciding where to switch first

What's included

  • Outdoor unit siting options and noise check
  • Recommended heat pump size and design flow temperature
  • Hot water cylinder sizing for your household
  • Room-by-room heat loss calculation using the MCS method
  • Written results in your quote, or a stand-alone report if you order one

For Sutton homes with extensions or loft conversions, each part of the house is assessed on its own construction.

Grants and rules for heat pumps in England

England

In England the Boiler Upgrade Scheme gives £7,500 towards an air source heat pump (£9,000 if it replaces oil or LPG, from 21 July 2026 to 31 March 2027), and since 28 April 2026 a valid EPC is no longer needed. The grant is applied for by the MCS-certified installer and shown as a deduction on your Sutton quote.

Installing heat pumps is zero-rated for VAT across the UK until 31 March 2027. Since 29 May 2025, permitted development in England allows up to two air source heat pumps on a house, each up to 1.5 m³, with no blanket 1 m boundary rule — the installation must still meet the MCS planning standards, including the noise check. Listed buildings, flats and some conservation-area positions need extra consent, which we check at survey.

Heat loss survey prices in Sutton

The ranges below are typical installed prices for homes in Greater London, including VAT. A survey sets the exact figure, because two similar-looking houses in Sutton can need quite different radiators and pipework.

Heat loss survey prices in Sutton
SurveyGuide price
Home survey and heat loss calculation with an installation quoteFree
Stand-alone heat loss survey and report£170–£450

Inc VAT. A stand-alone report is for homeowners who want the design without an installation quote.

Designing for Sutton's winters

7 h 51 minDaylight on the shortest day
16 h 37 minDaylight on the longest day
15°Noon sun height in December
51.36°NLatitude of Sutton

On the shortest day Sutton gets about 7 hours 51 minutes of daylight, and the winter sun reaches only around 15° above the horizon at noon. Winters this far south are milder than in most of the UK, which helps a heat pump run at low flow temperatures for much of the season.

What happens after you enquire in Sutton?

  1. Send your postcode and a few details, or use the guide price tool.
  2. A surveyor visits your Sutton home, measures every room and checks where the outdoor unit can go.
  3. You receive a heat loss design and a fixed written quote, with any grant shown where it applies.
  4. Installers fit the unit, cylinder and any radiator changes, typically over 2–4 days on site.
  5. The system is commissioned, set up with weather compensation and handed over with the paperwork.

Heat loss surveys in Sutton: questions

How soon can you survey a home in Sutton?

Survey dates depend on how busy installers are in Greater London. We offer the next available dates when you enquire and confirm them in writing.

How long does installation take in Sutton?

Most installations take 2–4 days on site. Jobs with several radiator changes or new pipework take longer, and your quote for a Sutton home states the expected time.

Where would the outdoor unit go on a Sutton house?

Usually at the side or rear, on a level base with space around it for airflow and servicing, away from bedroom windows where possible. The surveyor checks positions at your Sutton home.

Why can't you size the heat pump from my boiler?

Boilers are often much larger than a home's real heat loss, because they are sized for fast hot water and quick warm-ups. Matching a heat pump to the boiler's output usually means an oversized unit that costs more and switches on and off too often. A room-by-room calculation finds the actual heat demand, which is what the heat pump needs to meet.

What is a design flow temperature?

The design flow temperature is the temperature of the water sent to your radiators or underfloor heating on the coldest design day. Heat pumps are more efficient at lower flow temperatures, typically around 35–50°C. Choosing it is a balance: a lower figure improves efficiency but can mean larger radiators in some rooms, so the design shows both.

Ready to price your heat pump?

Use the guide price tool, or book a free home survey and fixed written quote.

CallGet a quote