Heat loss survey for Holyhead homes
Homes around Holyhead range from older terraces to newer estates, and each needs a different design. That is why we survey before we quote.
Homeowners in Holyhead thinking about insulation work can use the survey to see how it would change their heat pump size. A surveyor visits your Holyhead home to measure each room, window and wall before any heat pump is sized.
Every heat pump we quote starts with a room-by-room heat loss survey, free with installation enquiries and also available as a stand-alone report.
- Anyone getting a heat pump quote, as the first step
- Self-builders and architects who need emitter and system sizes early
- Homes with an existing heat pump that seems undersized or expensive to run
What's included
- Outdoor unit siting options and noise check
- Hot water cylinder sizing for your household
- Electrical supply and network operator notes
- Recommended heat pump size and design flow temperature
- Radiator schedule with any upgrades needed for each room
Design outdoor temperatures for Holyhead and the wider Gwynedd come from local cold-weather data, not a national average.
Grants and rules for heat pumps in Wales
In Wales the Boiler Upgrade Scheme gives £7,500 towards an air source heat pump (£9,000 if it replaces oil or LPG, from 21 July 2026 to 31 March 2027; £2,500 for air-to-air). The MCS-certified installer named in your quote applies to Ofgem for you, and the grant comes off your Holyhead quote.
There is no VAT on installing a heat pump anywhere in the UK, Wales included, until 31 March 2027. Planning rules for heat pumps in Wales are set by the Welsh Government and differ from England's, so the surveyor checks the unit position against them.
What to budget for heat loss surveys in Holyhead
Guide prices for Holyhead and the rest of Gwynedd are shown below, installed and inc VAT. We publish ranges rather than a single figure because design details move the price, and the written quote after survey fixes it.
| Survey | Guide price |
|---|---|
| Home survey and heat loss calculation with an installation quote | Free |
| Stand-alone heat loss survey and report | £150–£400 |
Inc VAT. A stand-alone report is for homeowners who want the design without an installation quote.
Winter daylight and heating in Holyhead
On the shortest day Holyhead gets about 7 hours 30 minutes of daylight, with the noon sun around 13° up. The heating season runs from autumn into spring, so a heat pump that is sized correctly and set up with weather compensation does most of its work in steady, cool conditions.
How installation works in Holyhead
- Send your postcode and a few details, or use the guide price tool.
- A surveyor visits your Holyhead home, measures every room and checks where the outdoor unit can go.
- You receive a heat loss design and a fixed written quote, with any grant shown where it applies.
- Installers fit the unit, cylinder and any radiator changes, typically over 2–4 days on site.
- The system is commissioned, set up with weather compensation and handed over with the paperwork.
Heat loss surveys in Holyhead: questions
Do I need new radiators for a heat pump in Holyhead?
Often some, not all. Heat pumps run best at lower water temperatures, so rooms with small radiators may need larger ones. The survey of your Holyhead home gives a room-by-room list.
Do you cover Llangefni as well as Holyhead?
Yes. We arrange surveys and installation in Llangefni, which is about 14 miles east of Holyhead, and across Gwynedd.
Where would the outdoor unit go on a Holyhead house?
Usually at the side or rear, on a level base with space around it for airflow and servicing, away from bedroom windows where possible. The surveyor checks positions at your Holyhead home.
Can I use the heat loss report to get other quotes?
Yes. A stand-alone heat loss report is yours to use, including sharing it with other installers so their quotes are based on the same figures. Comparing quotes like for like makes it easier to see differences in equipment, radiator upgrades and workmanship terms. The report states the assumptions used wherever construction could not be confirmed.
Will the survey check noise from the outdoor unit?
Yes. The surveyor identifies possible positions for the outdoor unit and carries out the MCS noise assessment, which estimates the sound level at the nearest neighbouring window from the unit's sound power level, distance and any barriers. In England, meeting the MCS planning standards is one of the conditions for permitted development. Wales, Scotland and Northern Ireland have their own rules, which we check.