Heat loss survey for Stevenage homes
Every property in Stevenage is different, so the design starts from measurements rather than a rule of thumb. That keeps the system the right size and the running costs predictable.
The survey in Stevenage includes a check of where the outdoor unit could sit and how its sound would reach neighbours. Design outdoor temperatures for Stevenage and the wider Hertfordshire come from local cold-weather data, not a national average.
Every heat pump we quote starts with a room-by-room heat loss survey, free with installation enquiries and also available as a stand-alone report.
- Self-builders and architects who need emitter and system sizes early
- Landlords comparing properties before deciding where to switch first
- Homeowners planning insulation or building work who want to know the effect on heat demand
What's included
- Hot water cylinder sizing for your household
- Radiator schedule with any upgrades needed for each room
- Outdoor unit siting options and noise check
- Written results in your quote, or a stand-alone report if you order one
- Room-by-room heat loss calculation using the MCS method
Houses in Stevenage built in different eras can need very different heat pump sizes, which is why each is calculated room by room.
Grants and rules for heat pumps in England
In England the Boiler Upgrade Scheme gives £7,500 towards an air source heat pump (£9,000 if it replaces oil or LPG, from 21 July 2026 to 31 March 2027), and since 28 April 2026 a valid EPC is no longer needed. The grant is applied for by the MCS-certified installer and shown as a deduction on your Stevenage quote.
Installing heat pumps is zero-rated for VAT across the UK until 31 March 2027. Since 29 May 2025, permitted development in England allows up to two air source heat pumps on a house, each up to 1.5 m³, with no blanket 1 m boundary rule — the installation must still meet the MCS planning standards, including the noise check. Listed buildings, flats and some conservation-area positions need extra consent, which we check at survey.
What to budget for heat loss surveys in Stevenage
Guide prices for Stevenage and the rest of Hertfordshire are shown below, installed and inc VAT. We publish ranges rather than a single figure because design details move the price, and the written quote after survey fixes it.
| Survey | Guide price |
|---|---|
| Home survey and heat loss calculation with an installation quote | Free |
| Stand-alone heat loss survey and report | £160–£420 |
Inc VAT. A stand-alone report is for homeowners who want the design without an installation quote.
Winter daylight and heating in Stevenage
On the shortest day Stevenage gets about 7 hours 45 minutes of daylight, with the noon sun around 15° up. The heating season runs from autumn into spring, so a heat pump that is sized correctly and set up with weather compensation does most of its work in steady, cool conditions.
How installation works in Stevenage
- Start online with a guide price or call us.
- A home survey in Stevenage gives us the room-by-room heat loss.
- Your written quote sets out the design, the price and the grant position where you live.
- Installation is booked for dates that suit you; most homes take 2–4 days on site.
- After commissioning you get a handover of the controls and settings, plus the certificates.
Heat loss surveys in Stevenage: questions
What size heat pump does a Stevenage home need?
It depends on the heat loss, not the postcode. As a rough guide, a 3 bedroom semi often needs 6–9 kW, but the room-by-room survey sets the actual size for your Stevenage home.
Where would the outdoor unit go on a Stevenage house?
Usually at the side or rear, on a level base with space around it for airflow and servicing, away from bedroom windows where possible. The surveyor checks positions at your Stevenage home.
Do I need new radiators for a heat pump in Stevenage?
Often some, not all. Heat pumps run best at lower water temperatures, so rooms with small radiators may need larger ones. The survey of your Stevenage home gives a room-by-room list.
What is a design flow temperature?
The design flow temperature is the temperature of the water sent to your radiators or underfloor heating on the coldest design day. Heat pumps are more efficient at lower flow temperatures, typically around 35–50°C. Choosing it is a balance: a lower figure improves efficiency but can mean larger radiators in some rooms, so the design shows both.
Will the survey check noise from the outdoor unit?
Yes. The surveyor identifies possible positions for the outdoor unit and carries out the MCS noise assessment, which estimates the sound level at the nearest neighbouring window from the unit's sound power level, distance and any barriers. In England, meeting the MCS planning standards is one of the conditions for permitted development. Wales, Scotland and Northern Ireland have their own rules, which we check.