Before you book: heat loss surveys in Arnold
Most homes can run on a heat pump if the system is designed properly, and Arnold is no different. The key is matching the heat pump and radiators to the home's heat loss.
A surveyor visits your Arnold home to measure each room, window and wall before any heat pump is sized. Homeowners in Arnold thinking about insulation work can use the survey to see how it would change their heat pump size.
Every heat pump we quote starts with a room-by-room heat loss survey, free with installation enquiries and also available as a stand-alone report.
- Landlords comparing properties before deciding where to switch first
- Homeowners planning insulation or building work who want to know the effect on heat demand
- Anyone getting a heat pump quote, as the first step
What's included
- Room-by-room heat loss calculation using the MCS method
- Electrical supply and network operator notes
- Outdoor unit siting options and noise check
- Radiator schedule with any upgrades needed for each room
- Hot water cylinder sizing for your household
For Arnold homes with extensions or loft conversions, each part of the house is assessed on its own construction.
Grants and rules for heat pumps in England
In England the Boiler Upgrade Scheme gives £7,500 towards an air source heat pump (£9,000 if it replaces oil or LPG, from 21 July 2026 to 31 March 2027), and since 28 April 2026 a valid EPC is no longer needed. The grant is applied for by the MCS-certified installer and shown as a deduction on your Arnold quote.
Installing heat pumps is zero-rated for VAT across the UK until 31 March 2027. Since 29 May 2025, permitted development in England allows up to two air source heat pumps on a house, each up to 1.5 m³, with no blanket 1 m boundary rule — the installation must still meet the MCS planning standards, including the noise check. Listed buildings, flats and some conservation-area positions need extra consent, which we check at survey.
Heat loss survey prices in Arnold
These are guide prices for Nottinghamshire, installed and including VAT. Your final price is fixed in a written quote after the survey and depends on the heat loss of the house, the radiators that need changing and where the unit goes.
| Survey | Guide price |
|---|---|
| Home survey and heat loss calculation with an installation quote | Free |
| Stand-alone heat loss survey and report | £150–£400 |
Inc VAT. A stand-alone report is for homeowners who want the design without an installation quote.
Short winter days in Arnold and what they mean
Arnold has about 7 hours 34 minutes of daylight at midwinter and 16 hours 56 minutes at midsummer. That swing matters if you pair a heat pump with solar panels: summer generation can cover much of the hot water, winter generation far less.
What happens after you enquire in Arnold?
- Start online with a guide price or call us.
- A home survey in Arnold gives us the room-by-room heat loss.
- Your written quote sets out the design, the price and the grant position where you live.
- Installation is booked for dates that suit you; most homes take 2–4 days on site.
- After commissioning you get a handover of the controls and settings, plus the certificates.
Heat loss surveys in Arnold: questions
Do you cover Nottingham as well as Arnold?
Yes. We arrange surveys and installation in Nottingham, which is about 3 miles south of Arnold, and across Nottinghamshire.
How long does a heat pump survey take in Arnold?
A home survey in Arnold usually takes one to two hours. The surveyor measures every heated room, checks windows, walls and radiators, and looks at where the outdoor unit and cylinder can go.
Where would the outdoor unit go on an Arnold house?
Usually at the side or rear, on a level base with space around it for airflow and servicing, away from bedroom windows where possible. The surveyor checks positions at your Arnold home.
What is a design flow temperature?
The design flow temperature is the temperature of the water sent to your radiators or underfloor heating on the coldest design day. Heat pumps are more efficient at lower flow temperatures, typically around 35–50°C. Choosing it is a balance: a lower figure improves efficiency but can mean larger radiators in some rooms, so the design shows both.
Why can't you size the heat pump from my boiler?
Boilers are often much larger than a home's real heat loss, because they are sized for fast hot water and quick warm-ups. Matching a heat pump to the boiler's output usually means an oversized unit that costs more and switches on and off too often. A room-by-room calculation finds the actual heat demand, which is what the heat pump needs to meet.