- Area
- West Sussex
- Postcode district
- RH11
- Nation
- England
- Guide price
- Priced after survey
- Survey
- Free for installation enquiries
Before you book: heat loss surveys in Crawley
Most homes can run on a heat pump if the system is designed properly, and Crawley is no different. The key is matching the heat pump and radiators to the home's heat loss.
A surveyor visits your Crawley home to measure each room, window and wall before any heat pump is sized. Homeowners in Crawley thinking about insulation work can use the survey to see how it would change their heat pump size.
Every heat pump we quote starts with a room-by-room heat loss survey, free with installation enquiries and also available as a stand-alone report.
- Self-builders and architects who need emitter and system sizes early
- Homes with an existing heat pump that seems undersized or expensive to run
- Homeowners planning insulation or building work who want to know the effect on heat demand
What's included
- Written results in your quote, or a stand-alone report if you order one
- Electrical supply and network operator notes
- Radiator schedule with any upgrades needed for each room
- Hot water cylinder sizing for your household
- Room-by-room heat loss calculation using the MCS method
The survey in Crawley includes a check of where the outdoor unit could sit and how its sound would reach neighbours.
Grants and rules for heat pumps in England
In England the Boiler Upgrade Scheme gives £7,500 towards an air source heat pump (£9,000 if it replaces oil or LPG, from 21 July 2026 to 31 March 2027), and since 28 April 2026 a valid EPC is no longer needed. The grant is applied for by the MCS-certified installer and shown as a deduction on your Crawley quote.
Installing heat pumps is zero-rated for VAT across the UK until 31 March 2027. Since 29 May 2025, permitted development in England allows up to two air source heat pumps on a house, each up to 1.5 m³, with no blanket 1 m boundary rule — the installation must still meet the MCS planning standards, including the noise check. Listed buildings, flats and some conservation-area positions need extra consent, which we check at survey.
Heat loss survey prices in Crawley
Guide prices for Crawley and the rest of West Sussex are shown below, installed and inc VAT. We publish ranges rather than a single figure because design details move the price, and the written quote after survey fixes it.
| Survey | Guide price |
|---|---|
| Home survey and heat loss calculation with an installation quote | Free |
| Stand-alone heat loss survey and report | £160–£420 |
Inc VAT. A stand-alone report is for homeowners who want the design without an installation quote.
Short winter days in Crawley and what they mean
On the shortest day Crawley gets about 7 hours 53 minutes of daylight, and the winter sun reaches only around 15° above the horizon at noon. Winters this far south are milder than in most of the UK, which helps a heat pump run at low flow temperatures for much of the season.
The steps for heat loss surveys in Crawley
- Send your postcode and a few details, or use the guide price tool.
- A surveyor visits your Crawley home, measures every room and checks where the outdoor unit can go.
- You receive a heat loss design and a fixed written quote, with any grant shown where it applies.
- Installers fit the unit, cylinder and any radiator changes, typically over 2–4 days on site.
- The system is commissioned, set up with weather compensation and handed over with the paperwork.
Heat loss surveys in Crawley: questions
What size heat pump does a Crawley home need?
It depends on the heat loss, not the postcode. As a rough guide, a 3 bedroom semi often needs 6–9 kW, but the room-by-room survey sets the actual size for your Crawley home.
Where would the outdoor unit go on a Crawley house?
Usually at the side or rear, on a level base with space around it for airflow and servicing, away from bedroom windows where possible. The surveyor checks positions at your Crawley home.
Do you cover Horley as well as Crawley?
Yes. We arrange surveys and installation in Horley, which is about 4 miles north of Crawley, and across West Sussex.
Will the survey check noise from the outdoor unit?
Yes. The surveyor identifies possible positions for the outdoor unit and carries out the MCS noise assessment, which estimates the sound level at the nearest neighbouring window from the unit's sound power level, distance and any barriers. In England, meeting the MCS planning standards is one of the conditions for permitted development. Wales, Scotland and Northern Ireland have their own rules, which we check.
How long does a heat loss survey take?
A typical survey takes 1–3 hours on site, depending on the size and complexity of the home. Larger or older houses with mixed construction, extensions or many rooms take longer. The calculations and design are completed afterwards, and the results are included in your quote or stand-alone report.

