Air source heat pumps, surveyed, designed and installed· Free home survey for installation enquiries
0800 088 6341
Heat pump radiators
West Midlands · WS9

Heat pump radiators in Aldridge

We cover Aldridge and the wider WS9 district for heat pump radiator upgrades. Start with a guide price online, then a free home survey for installation enquiries confirms the design.

Area
West Midlands
Postcode district
WS9
Nation
England
Guide price
From £250 inc VAT
Survey
Free for installation enquiries

Before you book: heat pump radiator upgrades in Aldridge

Homes around Aldridge range from older terraces to newer estates, and each needs a different design. That is why we survey before we quote.

Many older houses in Aldridge still have their original single-panel radiators, so the survey checks each one against the room it heats. We plan radiator upgrades in Aldridge so floorboards are lifted only where pipework genuinely needs changing.

We size each radiator to your room-by-room heat loss so a heat pump can heat your home at a low, efficient flow temperature.

  • Rooms with little wall space, where a fan-assisted radiator fits better
  • Rooms that already feel slow to heat, such as bay-windowed living rooms
  • Extensions and loft conversions with large areas of glazing

What's included

  • Pipework checks and any agreed pipe upgrades
  • A radiator schedule showing which radiators stay, which change and their outputs
  • Room-by-room heat loss figures for every heated room
  • Supply and fitting of new radiators, valves and brackets
  • Draining, refilling, cleaning and inhibitor treatment of the heating system

Extensions and kitchen-diners around Aldridge with large glazed areas get their own radiator calculation.

Grants and rules for heat pumps in England

England

Homes in Aldridge can use the Boiler Upgrade Scheme, which takes £7,500 off the cost of an air source heat pump when it replaces fossil-fuel or electric heating. Replacing oil or LPG heating qualifies for £9,000 for installations from 21 July 2026 to 31 March 2027, and air-to-air systems for £2,500. The MCS-certified installer named in your quote applies for the grant and deducts it from the price.

There is no VAT on installing a heat pump anywhere in the UK until 31 March 2027. In England most houses can have an air source heat pump under permitted development, provided the unit meets the MCS noise and siting standards; the old 1 m boundary limit was removed on 29 May 2025. We flag listed buildings, flats and sensitive conservation-area positions at survey.

Heat pump radiators costs around Aldridge

Here are typical prices for heat pump radiator upgrades in the West Midlands, installed and including VAT. Use the guide price tool for a figure based on your home, then a survey confirms it in writing.

Heat pump radiators costs around Aldridge
WorkGuide price
Replacement radiator, sized for a heat pump (each, fitted)£250–£450
Upgrade of about 10 radiators£2,000–£5,000
Pipework upgrade (e.g. microbore to larger bore)£1,500–£3,500

Installed, inc VAT. The survey lists which radiators need changing.

Winter daylight and heating in Aldridge

7 h 38 minDaylight on the shortest day
16 h 51 minDaylight on the longest day
14°Noon sun height in December
52.61°NLatitude of Aldridge

On the shortest day Aldridge gets about 7 hours 38 minutes of daylight, with the noon sun around 14° up. The heating season runs from autumn into spring, so a heat pump that is sized correctly and set up with weather compensation does most of its work in steady, cool conditions.

What happens after you enquire in Aldridge?

  1. Send your postcode and a few details, or use the guide price tool.
  2. A surveyor visits your Aldridge home, measures every room and checks where the outdoor unit can go.
  3. You receive a heat loss design and a fixed written quote, with any grant shown where it applies.
  4. Installers fit the unit, cylinder and any radiator changes, typically over 2–4 days on site.
  5. The system is commissioned, set up with weather compensation and handed over with the paperwork.

Heat pump radiator upgrades in Aldridge: questions

Where would the outdoor unit go on an Aldridge house?

Usually at the side or rear, on a level base with space around it for airflow and servicing, away from bedroom windows where possible. The surveyor checks positions at your Aldridge home.

What size heat pump does an Aldridge home need?

It depends on the heat loss, not the postcode. As a rough guide, a 3 bedroom semi often needs 6–9 kW, but the room-by-room survey sets the actual size for your Aldridge home.

Do you cover Walsall as well as Aldridge?

Yes. We arrange surveys and installation in Walsall, which is about 3 miles south-west of Aldridge, and across the West Midlands.

How much does a heat pump radiator cost?

A replacement radiator sized for a heat pump has a guide price of £250–£450 each, installed and including VAT. Upgrading about ten radiators in a typical home has a guide price of £2,000–£5,000. The final price is fixed in your written quote after the survey, once the radiator schedule shows exactly which radiators change.

Do I need new radiators for a heat pump?

Not necessarily: many homes keep most of their radiators and replace only a few. The heat loss survey checks each room against its existing radiator at the planned flow temperature. Rooms with large windows, high ceilings or extensions are the usual candidates for an upgrade, while bedrooms often need no change. Your radiator schedule lists every decision.

Ready to price your heat pump?

Use the guide price tool, or book a free home survey and fixed written quote.

CallGet a quote