- Area
- Kent
- Postcode district
- ME13
- Nation
- England
- Guide price
- From £90 inc VAT
- Visit
- Rate agreed in advance
Heat pump repairs for Faversham homes
Aftercare matters as much as installation. For a heat pump in Faversham the visit checks the outdoor unit, the water circuit and the controls, and the engineer explains any settings that would help the system run more efficiently.
We repair heat pumps in Faversham whoever installed them, including older monobloc and split systems. Heat pump owners in Faversham can arrange a fault-finding visit at a rate agreed before an engineer attends.
When a heat pump shows an error, loses pressure or stops heating, an engineer diagnoses the cause and explains the repair and its cost before fixing it.
- Rooms or hot water not getting warm enough
- Outdoor units that have become noisy, iced up or keep switching on and off
- Systems losing pressure or needing frequent topping up
What's included
- A clear explanation of the fault and a price for the repair before work goes ahead
- Reading of error history and operating data
- Fault-finding visit at a rate agreed before attending
- System refill, venting and recommissioning after the repair
- Supply and fitting of replacement parts
Across Faversham and Kent, refrigerant repairs on split systems are carried out by an F-gas certified engineer.
Grants and rules for heat pumps in England
Homes in Faversham can use the Boiler Upgrade Scheme, which takes £7,500 off the cost of an air source heat pump when it replaces fossil-fuel or electric heating. Replacing oil or LPG heating qualifies for £9,000 for installations from 21 July 2026 to 31 March 2027, and air-to-air systems for £2,500. The MCS-certified installer named in your quote applies for the grant and deducts it from the price.
Guide prices for heat pump repairs in Faversham
These are guide prices including VAT. The rate for your visit in Faversham is confirmed before we book it, and any repair is priced in writing before parts are ordered.
| Repair | Guide price |
|---|---|
| Fault-finding visit and diagnosis | £90–£190 |
| Sensor or thermistor replacement | £120–£290 |
| Expansion vessel or pressure relief valve | £150–£360 |
| Circulating pump replacement | £260–£490 |
| Fan motor replacement | £310–£670 |
| Refrigerant leak repair and re-gas (split systems) | £360–£980 |
| Main control board (PCB) replacement | £460–£1,150 |
Inc VAT. The fault-finding rate is agreed before we attend; repairs are priced in writing before parts are ordered.
Short winter days in Faversham and what they mean
Faversham sees roughly 7 hours 51 minutes of daylight in late December against 16 hours 36 minutes in June. Milder southern winters suit heat pumps well, though the system is still sized for a cold snap rather than an average day.
Booking a visit in Faversham
- Tell us the make if you know it, the error code or symptoms, and send photos of the unit and controller.
- We confirm the fault-finding rate and arrange a visit in Faversham.
- The engineer diagnoses the fault and gives you a written price for the repair.
- Parts are ordered once you agree, and the repair is completed and tested.
Heat pump repairs in Faversham: questions
How much does a visit cost in Faversham?
The rate for a service or fault-finding visit is agreed before anyone attends. Any repair is priced in writing before parts are ordered, so you decide before work goes ahead.
Will the engineer need access indoors as well as outside?
Usually yes. The outdoor unit, the hot water cylinder, the controls and the pipework and valves indoors are all part of the visit, so allow access to each.
Can you work on a heat pump in Faversham that someone else installed?
Yes. We arrange servicing and repairs for most air source heat pumps in Faversham, whoever fitted them. Tell us the make and model when you get in touch.
Do refrigerant repairs need a specialist?
Yes. Any work on a heat pump's refrigerant circuit, such as tracing a leak, replacing a component or re-gassing, must by law be done by an F-gas certified engineer where the refrigerant is fluorinated, such as R32; units using R290 (propane) need an engineer trained in flammable refrigerants. On split systems the refrigerant runs through pipes inside your home, so leaks there are more likely than on sealed monobloc units.
Why does my heat pump keep switching on and off?
Frequent starting and stopping, called short cycling, is usually caused by an oversized heat pump, low water flow, too many zones closing at once or controls set with too narrow a range. It reduces efficiency and wears components. An engineer can check the settings, flow rates and design, and can often improve it with control changes before any parts are needed.

