Before you book: heat pump repairs in Sevenoaks
A heat pump that is serviced and set up properly keeps running efficiently for many years. Many heat pump faults trace back to settings, low pressure or a worn part rather than the heat pump itself, and those can usually be put right.
Heat pump owners in Sevenoaks can arrange a fault-finding visit at a rate agreed before an engineer attends. Outdoor units in exposed spots around Sevenoaks can ice more heavily, so siting is checked as part of any icing fault.
When a heat pump shows an error, loses pressure or stops heating, an engineer diagnoses the cause and explains the repair and its cost before fixing it.
- Systems losing pressure or needing frequent topping up
- Rooms or hot water not getting warm enough
- Outdoor units that have become noisy, iced up or keep switching on and off
What's included
- Refrigerant repairs by an F-gas certified engineer where needed
- Fault-finding visit at a rate agreed before attending
- Testing of sensors, pumps, valves, pressures and electrics
- Supply and fitting of replacement parts
- A clear explanation of the fault and a price for the repair before work goes ahead
Repairs in Sevenoaks that need a part ordered are explained and priced before the engineer leaves.
Grants and rules for heat pumps in England
In England the Boiler Upgrade Scheme gives £7,500 towards an air source heat pump (£9,000 if it replaces oil or LPG, from 21 July 2026 to 31 March 2027), and since 28 April 2026 a valid EPC is no longer needed. The grant is applied for by the MCS-certified installer and shown as a deduction on your Sevenoaks quote.
Heat pump repairs costs around Sevenoaks
Guide prices for Kent, including VAT. We agree the visit rate before anyone attends, so there are no surprises on the day.
| Repair | Guide price |
|---|---|
| Fault-finding visit and diagnosis | £90–£190 |
| Sensor or thermistor replacement | £120–£290 |
| Expansion vessel or pressure relief valve | £150–£360 |
| Circulating pump replacement | £260–£490 |
| Fan motor replacement | £310–£670 |
| Refrigerant leak repair and re-gas (split systems) | £360–£980 |
| Main control board (PCB) replacement | £460–£1,150 |
Inc VAT. The fault-finding rate is agreed before we attend; repairs are priced in writing before parts are ordered.
Designing for Sevenoaks's winters
On the shortest day Sevenoaks gets about 7 hours 52 minutes of daylight, and the winter sun reaches only around 15° above the horizon at noon. Winters this far south are milder than in most of the UK, which helps a heat pump run at low flow temperatures for much of the season.
Booking a visit in Sevenoaks
- Tell us the make if you know it, the error code or symptoms, and send photos of the unit and controller.
- We confirm the fault-finding rate and arrange a visit in Sevenoaks.
- The engineer diagnoses the fault and gives you a written price for the repair.
- Parts are ordered once you agree, and the repair is completed and tested.
Heat pump repairs in Sevenoaks: questions
Will the engineer need access indoors as well as outside?
Usually yes. The outdoor unit, the hot water cylinder, the controls and the pipework and valves indoors are all part of the visit, so allow access to each.
What should I check before booking a visit in Sevenoaks?
Note any error code on the controller, check the system pressure gauge if you have one, and make sure the outdoor unit is clear of leaves or snow. Photos of the unit and controller help.
Do you also cover Westerham?
Yes. We arrange heat pump servicing and repairs in Westerham, which is about 5 miles west of Sevenoaks, and across Kent.
Is ice on my heat pump a fault?
Some frost on the outdoor unit in cold, damp weather is normal, and the unit clears it with regular defrost cycles, often releasing a little vapour. It becomes a fault when thick ice builds up and does not clear, or when ice blocks the fan. That can point to poor airflow, a failed sensor, drainage problems or low refrigerant, and needs checking.
Why does my heat pump keep switching on and off?
Frequent starting and stopping, called short cycling, is usually caused by an oversized heat pump, low water flow, too many zones closing at once or controls set with too narrow a range. It reduces efficiency and wears components. An engineer can check the settings, flow rates and design, and can often improve it with control changes before any parts are needed.