Air source heat pumps, surveyed, designed and installed· Free home survey for installation enquiries
0800 088 6341
New-build and self-build heat pumps
England · 14 towns

New-build and self-build heat pumps in West Sussex

Switching to a heat pump in West Sussex? Start with a guide price, then a surveyor measures your home and the written quote fixes the price.

New homes in England are being built to tighter carbon standards, and Wales, Scotland and Northern Ireland each set their own building regulations; a heat pump is one of the main ways new homes meet them. We work from your architect's drawings and energy assessment, then fit in with the build programme: first-fix pipework before floors and walls are finished, and the outdoor unit, cylinder and controls once the building is weathertight.

New homes in West Sussex designed with underfloor heating downstairs get a low flow temperature that suits a heat pump. For barn conversions and replacement dwellings near West Sussex, the design starts from the specification of the new walls, floors and glazing. Builders working across West Sussex can coordinate first and second fix with an installer covering West Sussex.

Who it suits

  • Small builders and developers working on one-off homes or small groups
  • Architects and builders who want a heat loss design from the drawings
  • Homes designed with underfloor heating on one or more floors
  • Self-builders planning heating alongside the structure

Grants and rules for heat pumps in England

England

Homes in West Sussex can use the Boiler Upgrade Scheme, which takes £7,500 off the cost of an air source heat pump when it replaces fossil-fuel or electric heating. Replacing oil or LPG heating qualifies for £9,000 for installations from 21 July 2026 to 31 March 2027, and air-to-air systems for £2,500. The MCS-certified installer named in your quote applies for the grant and deducts it from the price.

There is no VAT on installing a heat pump anywhere in the UK until 31 March 2027. In England most houses can have an air source heat pump under permitted development, provided the unit meets the MCS noise and siting standards; the old 1 m boundary limit was removed on 29 May 2025. We flag listed buildings, flats and sensitive conservation-area positions at survey.

New-build and self-build heat pumps prices in West Sussex

These are guide prices for West Sussex, installed and including VAT. Your final price is fixed in a written quote after the survey and depends on the heat loss of the house, the radiators that need changing and where the unit goes.

New-build and self-build heat pumps prices in West Sussex
HomeTypical sizeInstalled guide price
1–2 bedroom flat or small terrace4–5 kW£9,900–£13,000
2–3 bedroom terrace or semi5–7 kW£10,900–£14,050
3 bedroom semi or small detached6–9 kW£12,500–£16,100
4 bedroom detached8–12 kW£14,550–£18,700
5+ bedroom or larger older house11–16 kW£17,150–£23,400

Installed, inc VAT: unit, cylinder, controls, minor pipework and commissioning. Most new builds are not eligible for grant funding, so no deduction is shown.

Towns we cover in West Sussex

We cover 14 towns in West Sussex for new-build and self-build heat pumps. Each links to local guide prices and the grant position for England.

TownPostcode districtNearest townMidwinter daylight
CrawleyRH11Horley7 h 53 min
WorthingBN11Shoreham-by-Sea7 h 56 min
Bognor RegisPO21Chichester7 h 57 min
LittlehamptonBN17Arundel7 h 56 min
HorshamRH12Crawley7 h 54 min
Haywards HeathRH16Burgess Hill7 h 55 min
ChichesterPO19Bognor Regis7 h 56 min
Burgess HillRH15Haywards Heath7 h 55 min
East GrinsteadRH19Crawley7 h 53 min
Shoreham-by-SeaBN43Worthing7 h 56 min
EmsworthPO10Havant7 h 56 min
ArundelBN18Littlehampton7 h 56 min
MidhurstGU29Petworth7 h 55 min
PetworthGU28Midhurst7 h 55 min

New-build and self-build heat pumps questions

When do you need to be involved in a new build?

Ideally before the drawings are finalised, so the plant space, outdoor unit position and emitters are agreed with your architect. At the latest, the design should be done before first fix, when pipework goes in under floors and inside walls. Late involvement usually means compromises, such as a cylinder in an awkward space or pipe runs boxed in afterwards.

Do new builds have to have a heat pump?

The rules depend on the nation and when your project was approved, so check with your architect or building control. New homes in England are being built to tighter carbon standards, and Wales, Scotland and Northern Ireland set their own building regulations. A heat pump is one of the main ways new homes meet these standards, and we design the heating to whichever applies.

How long does a new-build heat pump installation take?

It is split across the build. First fix typically takes a few days once the structure is up, and second fix with commissioning takes a few more days near completion. Underfloor heating in screed then follows a gradual drying-out schedule. Exact timing depends on your build programme, which we agree with your builder so trades are not left waiting on each other.

Where should the outdoor unit go on a new build?

Somewhere with free airflow, a solid base and drainage, away from bedroom windows and boundaries where possible, and positioned to pass the MCS noise assessment. On a new build this can be planned into the landscaping, such as a side return or screened area near the plant room, which keeps pipe runs short. Planning rules differ by nation, so we check the position at design stage.

Ready to price your heat pump?

Use the guide price tool, or book a free home survey and fixed written quote.

CallGet a quote