- Area
- Bedfordshire
- Postcode district
- SG18
- Nation
- England
- Guide price
- From £9,700 inc VAT
- Survey
- Free for installation enquiries
Air source heat pump installation for Biggleswade homes
Homes around Biggleswade range from older terraces to newer estates, and each needs a different design. That is why we survey before we quote.
Terraced streets in Biggleswade often mean a compact unit position at the rear, so siting and sound levels are checked carefully. Installers working in Biggleswade plan the order of work so heating and hot water are off for as short a time as practical.
We survey your home, design a heat pump system around its real heat loss, and manage the installation from the first visit to the MCS certificate.
- Homes replacing a gas, oil, LPG or electric heating system
- Owners and landlords in England and Wales eligible for the Boiler Upgrade Scheme
- Owners who want one contract covering design, fitting and paperwork
What's included
- MCS registration and certificate, plus network operator notification
- Free home survey and room-by-room heat loss calculation
- Radiator and pipework changes where the design needs them
- Removal of the old boiler or heaters
- Boiler Upgrade Scheme application in England and Wales where eligible
For older properties in Biggleswade, the heat loss calculation looks closely at solid walls, single glazing and draughts before any unit is sized.
Grants and rules for heat pumps in England
Homes in Biggleswade can use the Boiler Upgrade Scheme, which takes £7,500 off the cost of an air source heat pump when it replaces fossil-fuel or electric heating. Replacing oil or LPG heating qualifies for £9,000 for installations from 21 July 2026 to 31 March 2027, and air-to-air systems for £2,500. The MCS-certified installer named in your quote applies for the grant and deducts it from the price.
There is no VAT on installing a heat pump anywhere in the UK until 31 March 2027. In England most houses can have an air source heat pump under permitted development, provided the unit meets the MCS noise and siting standards; the old 1 m boundary limit was removed on 29 May 2025. We flag listed buildings, flats and sensitive conservation-area positions at survey.
Guide prices for air source heat pump installation in Biggleswade
Here are typical prices for air source heat pump installation in Bedfordshire, installed and including VAT. Use the guide price tool for a figure based on your home, then a survey confirms it in writing.
| Home | Typical size | Installed guide price | After £7,500 grant |
|---|---|---|---|
| 1–2 bedroom flat or small terrace | 4–5 kW | £9,700–£12,750 | £2,200–£5,250 |
| 2–3 bedroom terrace or semi | 5–7 kW | £10,700–£13,750 | £3,200–£6,250 |
| 3 bedroom semi or small detached | 6–9 kW | £12,250–£15,800 | £4,750–£8,300 |
| 4 bedroom detached | 8–12 kW | £14,300–£18,350 | £6,800–£10,850 |
| 5+ bedroom or larger older house | 11–16 kW | £16,850–£22,950 | £9,350–£15,450 |
Installed, inc VAT: unit, cylinder, controls, minor pipework and commissioning.
Short winter days in Biggleswade and what they mean
On the shortest day Biggleswade gets about 7 hours 43 minutes of daylight, with the noon sun around 14° up. The heating season runs from autumn into spring, so a heat pump that is sized correctly and set up with weather compensation does most of its work in steady, cool conditions.
From survey to switch-on in Biggleswade
- Send your postcode and a few details, or use the guide price tool.
- A surveyor visits your Biggleswade home, measures every room and checks where the outdoor unit can go.
- You receive a heat loss design and a fixed written quote, with any grant shown where it applies.
- Installers fit the unit, cylinder and any radiator changes, typically over 2–4 days on site.
- The system is commissioned, set up with weather compensation and handed over with the paperwork.
Air source heat pump installation in Biggleswade: questions
How long does a heat pump survey take in Biggleswade?
A home survey in Biggleswade usually takes one to two hours. The surveyor measures every heated room, checks windows, walls and radiators, and looks at where the outdoor unit and cylinder can go.
Where would the outdoor unit go on a Biggleswade house?
Usually at the side or rear, on a level base with space around it for airflow and servicing, away from bedroom windows where possible. The surveyor checks positions at your Biggleswade home.
Do you cover Sandy as well as Biggleswade?
Yes. We arrange surveys and installation in Sandy, which is about 3 miles north of Biggleswade, and across Bedfordshire.
Can I cancel after accepting the quote?
Nothing is ordered until you accept the written quote. Where the contract is agreed away from our premises, for example at your kitchen table, you can cancel within 14 days under the Consumer Contracts Regulations 2013. If you ask us to start sooner and then cancel, you pay only for work done up to that point.
How long does an air source heat pump installation take?
A typical home installation takes 2–4 days on site. It takes longer if several radiators are being replaced, pipework is being upgraded or the cylinder is going in a new location. Your quote sets out the expected programme, including when you will be without heating and hot water. Timings are typical rather than fixed, because older homes sometimes reveal surprises once floorboards are lifted.

