Air source heat pumps, surveyed, designed and installed· Free home survey for installation enquiries
0800 088 6341
Heat loss survey
Greater Manchester · WN7

Heat loss survey in Leigh

Heat loss survey for homes in Leigh and nearby Atherton: every quote lists what is included and what the grant position is where you live.

Area
Greater Manchester
Postcode district
WN7
Nation
England
Guide price
Priced after survey
Survey
Free for installation enquiries

Heat loss survey in Leigh: what to expect

In Leigh, as anywhere in the UK, the heat pumps that perform well are the ones designed around low flow temperatures and sized from a proper heat loss calculation.

The survey in Leigh includes a check of where the outdoor unit could sit and how its sound would reach neighbours. Design outdoor temperatures for Leigh and the wider Greater Manchester come from local cold-weather data, not a national average.

Every heat pump we quote starts with a room-by-room heat loss survey, free with installation enquiries and also available as a stand-alone report.

  • Homeowners planning insulation or building work who want to know the effect on heat demand
  • Self-builders and architects who need emitter and system sizes early
  • Anyone getting a heat pump quote, as the first step

What's included

  • Room-by-room heat loss calculation using the MCS method
  • Electrical supply and network operator notes
  • Written results in your quote, or a stand-alone report if you order one
  • Outdoor unit siting options and noise check
  • Radiator schedule with any upgrades needed for each room

Homeowners in Leigh thinking about insulation work can use the survey to see how it would change their heat pump size.

Grants and rules for heat pumps in England

England

In England the Boiler Upgrade Scheme gives £7,500 towards an air source heat pump (£9,000 if it replaces oil or LPG, from 21 July 2026 to 31 March 2027), and since 28 April 2026 a valid EPC is no longer needed. The grant is applied for by the MCS-certified installer and shown as a deduction on your Leigh quote.

Installing heat pumps is zero-rated for VAT across the UK until 31 March 2027. Since 29 May 2025, permitted development in England allows up to two air source heat pumps on a house, each up to 1.5 m³, with no blanket 1 m boundary rule — the installation must still meet the MCS planning standards, including the noise check. Listed buildings, flats and some conservation-area positions need extra consent, which we check at survey.

Heat loss survey costs around Leigh

The ranges below are typical installed prices for homes in Greater Manchester, including VAT. A survey sets the exact figure, because two similar-looking houses in Leigh can need quite different radiators and pipework.

Heat loss survey costs around Leigh
SurveyGuide price
Home survey and heat loss calculation with an installation quoteFree
Stand-alone heat loss survey and report£150–£390

Inc VAT. A stand-alone report is for homeowners who want the design without an installation quote.

How long is the heating season in Leigh?

7 h 28 minDaylight on the shortest day
17 h 02 minDaylight on the longest day
13°Noon sun height in December
53.50°NLatitude of Leigh

On the shortest day Leigh gets only about 7 hours 28 minutes of daylight and the noon sun sits around 13° above the horizon. Northern winters tend to be longer, so a well-designed, efficient system matters more here because it runs for more of the year.

From survey to switch-on in Leigh

  1. Send your postcode and a few details, or use the guide price tool.
  2. A surveyor visits your Leigh home, measures every room and checks where the outdoor unit can go.
  3. You receive a heat loss design and a fixed written quote, with any grant shown where it applies.
  4. Installers fit the unit, cylinder and any radiator changes, typically over 2–4 days on site.
  5. The system is commissioned, set up with weather compensation and handed over with the paperwork.

Heat loss surveys in Leigh: questions

Do I need new radiators for a heat pump in Leigh?

Often some, not all. Heat pumps run best at lower water temperatures, so rooms with small radiators may need larger ones. The survey of your Leigh home gives a room-by-room list.

What size heat pump does a Leigh home need?

It depends on the heat loss, not the postcode. As a rough guide, a 3 bedroom semi often needs 6–9 kW, but the room-by-room survey sets the actual size for your Leigh home.

How long does installation take in Leigh?

Most installations take 2–4 days on site. Jobs with several radiator changes or new pipework take longer, and your quote for a Leigh home states the expected time.

Can I use the heat loss report to get other quotes?

Yes. A stand-alone heat loss report is yours to use, including sharing it with other installers so their quotes are based on the same figures. Comparing quotes like for like makes it easier to see differences in equipment, radiator upgrades and workmanship terms. The report states the assumptions used wherever construction could not be confirmed.

Will the survey check noise from the outdoor unit?

Yes. The surveyor identifies possible positions for the outdoor unit and carries out the MCS noise assessment, which estimates the sound level at the nearest neighbouring window from the unit's sound power level, distance and any barriers. In England, meeting the MCS planning standards is one of the conditions for permitted development. Wales, Scotland and Northern Ireland have their own rules, which we check.

Ready to price your heat pump?

Use the guide price tool, or book a free home survey and fixed written quote.