- Area
- Greater Manchester
- Postcode district
- WN1
- Nation
- England
- Guide price
- From £240 inc VAT
- Survey
- Free for installation enquiries
Heat pump radiators in Wigan: what to expect
Every property in Wigan is different, so the design starts from measurements rather than a rule of thumb. That keeps the system the right size and the running costs predictable.
In Wigan, bay-windowed front rooms are often the rooms that need a larger radiator when moving to a heat pump. Radiator fitting in Wigan is scheduled with your heat pump installation so the system is drained only once.
We size each radiator to your room-by-room heat loss so a heat pump can heat your home at a low, efficient flow temperature.
- Rooms that already feel slow to heat, such as bay-windowed living rooms
- Rooms with little wall space, where a fan-assisted radiator fits better
- Homes switching from a gas, oil or LPG boiler to a heat pump
What's included
- Room-by-room heat loss figures for every heated room
- Draining, refilling, cleaning and inhibitor treatment of the heating system
- Making good around brackets and pipe routes, with any decorating agreed in your quote
- Supply and fitting of new radiators, valves and brackets
- A radiator schedule showing which radiators stay, which change and their outputs
Many older houses in Wigan still have their original single-panel radiators, so the survey checks each one against the room it heats.
Grants and rules for heat pumps in England
Homes in Wigan can use the Boiler Upgrade Scheme, which takes £7,500 off the cost of an air source heat pump when it replaces fossil-fuel or electric heating. Replacing oil or LPG heating qualifies for £9,000 for installations from 21 July 2026 to 31 March 2027, and air-to-air systems for £2,500. The MCS-certified installer named in your quote applies for the grant and deducts it from the price.
Installing heat pumps is zero-rated for VAT across the UK until 31 March 2027. Since 29 May 2025, permitted development in England allows up to two air source heat pumps on a house, each up to 1.5 m³, with no blanket 1 m boundary rule — the installation must still meet the MCS planning standards, including the noise check. Listed buildings, flats and some conservation-area positions need extra consent, which we check at survey.
Heat pump radiators prices in Wigan
Here are typical prices for heat pump radiator upgrades in Greater Manchester, installed and including VAT. Use the guide price tool for a figure based on your home, then a survey confirms it in writing.
| Work | Guide price |
|---|---|
| Replacement radiator, sized for a heat pump (each, fitted) | £240–£440 |
| Upgrade of about 10 radiators | £1,950–£4,900 |
| Pipework upgrade (e.g. microbore to larger bore) | £1,450–£3,450 |
Installed, inc VAT. The survey lists which radiators need changing.
Short winter days in Wigan and what they mean
On the shortest day Wigan gets only about 7 hours 27 minutes of daylight and the noon sun sits around 13° above the horizon. Northern winters tend to be longer, so a well-designed, efficient system matters more here because it runs for more of the year.
The steps for heat pump radiator upgrades in Wigan
- Start online with a guide price or call us.
- A home survey in Wigan gives us the room-by-room heat loss.
- Your written quote sets out the design, the price and the grant position where you live.
- Installation is booked for dates that suit you; most homes take 2–4 days on site.
- After commissioning you get a handover of the controls and settings, plus the certificates.
Heat pump radiator upgrades in Wigan: questions
How long does installation take in Wigan?
Most installations take 2–4 days on site. Jobs with several radiator changes or new pipework take longer, and your quote for a Wigan home states the expected time.
Where would the outdoor unit go on a Wigan house?
Usually at the side or rear, on a level base with space around it for airflow and servicing, away from bedroom windows where possible. The surveyor checks positions at your Wigan home.
What size heat pump does a Wigan home need?
It depends on the heat loss, not the postcode. As a rough guide, a 3 bedroom semi often needs 6–9 kW, but the room-by-room survey sets the actual size for your Wigan home.
Are fan-assisted radiators noisy?
Fan-assisted radiators make a low, steady fan sound when running at higher output, and many have quieter settings for bedrooms at night. They are useful where wall space is short, such as a kitchen with few clear walls. They need a small electrical supply, which we plan into the installation if you choose them.
Can radiators be changed without draining the whole system?
Radiator changes normally mean draining the heating system, which is why they are usually done as part of the heat pump installation. The system is then refilled, flushed, treated with inhibitor and balanced. Doing the radiators at the same time avoids draining twice and means the new radiators are commissioned with the heat pump.

