Underfloor heating can cover one room, an extension or the whole ground floor, and it works alongside radiators upstairs. We design it from the same room-by-room heat loss figures as the rest of the system, set out pipe spacing and zones for each room, and confirm which floor finishes will let the heat through.
We coordinate with builders working in South Glamorgan so underfloor pipes are laid and tested before the screed goes down. Every underfloor design for South Glamorgan starts with the floor finish you plan to lay, from tiles to carpet. Older houses around South Glamorgan with suspended timber floors can often take underfloor pipes between the joists.
Who it suits
- Extensions, especially open-plan kitchen-diners with large glazed areas
- Self-builds and new floors where insulation and screed are going in anyway
- Ground floors being dug out or relaid as part of wider building work
- Rooms where wall space for radiators is scarce
Grants and rules for heat pumps in Wales
Homes in South Glamorgan can use the Boiler Upgrade Scheme, which applies in Wales as well as England: £7,500 towards an air source heat pump, or £9,000 when it replaces oil or LPG heating for installations from 21 July 2026 to 31 March 2027. The MCS-certified installer named in your quote applies and deducts the grant.
Installing heat pumps is zero-rated for VAT across the UK until 31 March 2027. Wales has its own permitted development rules for air source heat pumps, so we check what applies to your property, including listed building and conservation-area constraints, at the survey.
Underfloor heating with heat pumps prices in South Glamorgan
These are guide prices for South Glamorgan, installed and including VAT. Your final price is fixed in a written quote after the survey and depends on the heat loss of the house, the radiators that need changing and where the unit goes.
| Work | Guide price |
|---|---|
| Wet underfloor heating, one room | £1,500–£3,500 |
| Wet underfloor heating, whole ground floor | £5,000–£15,000 |
Installed, inc VAT. Floor finishes and screed drying time are confirmed at survey.
Towns we cover in South Glamorgan
We cover 6 towns in South Glamorgan for underfloor heating with a heat pump. Each links to local guide prices and the grant position for Wales.
| Town | Postcode district | Nearest town | Midwinter daylight |
|---|---|---|---|
| Cardiff | CF10 | Penarth | 7 h 50 min |
| Barry | CF62 | Dinas Powys | 7 h 51 min |
| Penarth | CF64 | Dinas Powys | 7 h 50 min |
| Cowbridge | CF71 | Llantwit Major | 7 h 50 min |
| Dinas Powys | CF64 | Penarth | 7 h 50 min |
| Llantwit Major | CF61 | Cowbridge | 7 h 50 min |
Underfloor heating with a heat pump questions
Can I put carpet over underfloor heating?
Yes, as long as the carpet and underlay together have a low tog rating, which measures how much they resist heat. For heat pump systems a combined figure of around 1.5 tog or less is a common target. Thick carpet on heavy underlay can cut output noticeably, so rooms with carpet may need closer pipe spacing.
How much will an overlay system raise my floor?
A low-profile overlay system typically adds around 15–25 mm for the boards, plus the thickness of the new floor finish. That can be enough to need door trimming, threshold strips and adjustments where the floor meets kitchen units or stairs. We measure these details at the survey so the build-up is agreed before work starts.
How much does underfloor heating cost with a heat pump?
Wet underfloor heating for a whole ground floor has a guide price of £5,000–£15,000, installed and including VAT, and a single room has a guide price of £1,500–£3,500. The spread reflects floor type, area, whether an overlay or screed system is used and how much floor preparation is needed. Your written quote fixes the price after the survey.
Can I heat just one room with underfloor heating?
Yes. A single room, such as a kitchen extension, can have its own underfloor zone connected to the heat pump alongside the radiators in the rest of the house. It needs its own thermostat and a manifold, which for one room can be compact. The design checks the room's heat loss so the floor can meet it at the system's flow temperature.

