Design starts with the load: a heat loss calculation for the building, its occupancy and opening hours, how much hot water it uses and whether any spaces need cooling. From that we propose plant sizes and positions, on a roof, in a yard or in a plant enclosure, with the structural, electrical and noise checks each position needs. Larger plant may need a three-phase supply, which the network operator may need to provide or confirm.
Premises in Lanarkshire close to homes need careful plant siting and, where required, an acoustic assessment. For blocks of flats in Lanarkshire, we assess whether individual units or a communal system suits the building and how it is managed. Landlords and managing agents in Lanarkshire can phase the work to keep tenants and staff comfortable during the switchover.
Who it suits
- Blocks of flats and houses in multiple occupation needing shared or per-flat systems
- Premises that also want cooling in some areas
- Buildings with roof or yard space for outdoor plant
- Offices, shops and small commercial premises replacing gas or oil boilers
Grants and rules for heat pumps in Scotland
In Scotland, heat pump funding comes through Home Energy Scotland rather than the Boiler Upgrade Scheme: a grant of up to £7,500 (up to £1,500 extra for eligible rural and island homes) and an optional interest-free loan of up to £7,500. For a home in Lanarkshire, apply and receive the written offer before the installation date is fixed.
There is no VAT on installing a heat pump anywhere in the UK, Scotland included, until 31 March 2027. Scottish permitted development rules and building standards apply, and the surveyor checks the unit position and any listed or conservation-area constraints.
Prices
Commercial systems are priced after a site survey and load calculation.
Towns we cover in Lanarkshire
We cover 13 towns in Lanarkshire for commercial heat pump installation. Each links to local guide prices and the grant position for Scotland.
| Town | Postcode district | Nearest town | Midwinter daylight |
|---|---|---|---|
| East Kilbride | G74 | Cambuslang | 7 h 00 min |
| Hamilton | ML3 | Motherwell | 7 h 00 min |
| Cumbernauld | G67 | Airdrie | 6 h 57 min |
| Coatbridge | ML5 | Airdrie | 6 h 59 min |
| Airdrie | ML6 | Coatbridge | 6 h 59 min |
| Motherwell | ML1 | Bellshill | 7 h 00 min |
| Rutherglen | G73 | Cambuslang | 6 h 59 min |
| Cambuslang | G73 | Rutherglen | 6 h 59 min |
| Wishaw | ML2 | Motherwell | 7 h 00 min |
| Bellshill | ML4 | Motherwell | 6 h 59 min |
| Carluke | ML8 | Wishaw | 7 h 00 min |
| Lanark | ML11 | Carluke | 7 h 01 min |
| Strathaven | ML10 | Hamilton | 7 h 01 min |
Commercial heat pump installation questions
Can you install without closing the business?
Usually, yes. Outdoor plant, pipework and controls can often be installed while the existing heating still runs, with the switchover planned for a short window, such as a weekend or a quieter time of year. Work inside occupied areas can be phased. The programme in your quote sets out what happens when, so you can plan staff and customers around it.
Can heat pumps go on a flat roof?
Yes, flat roofs are a common position for commercial plant. The roof needs a structural check for the weight of the units and their frames, and the installation usually needs a lifting plan, anti-vibration mounts, drainage for defrost water and safe access for maintenance. Pipe and cable routes from the roof into the building are planned at survey.
Can commercial heat pumps provide cooling as well?
Some can. Air-to-water heat pumps are mainly used for heating and hot water, but certain units can also supply chilled water for fan coil units. Air-to-air systems heat and cool directly through indoor units and suit offices and shops where cooling is wanted. The survey identifies which areas need cooling and recommends a system to match.
What is a cascaded heat pump system?
A cascaded system links two or more outdoor heat pump units to one controller, which runs as many units as demand needs. On mild days one unit might run; on cold days all of them. This keeps each unit working efficiently, spreads wear across the units and means heating can usually continue at reduced output if one unit needs repair or servicing.