Air source heat pumps, surveyed, designed and installed· Free home survey for installation enquiries
0800 088 6341
Heat loss survey
England · 18 towns

Heat loss survey in Devon

We arrange air source heat pumps for homes throughout Devon, from the first heat loss survey to commissioning and annual servicing.

Getting the size right matters. An undersized heat pump struggles in cold weather, while an oversized one costs more to buy and can switch on and off frequently, which wastes energy and wears components. Sizing from a rule of thumb, or simply matching the old boiler's output, is a common cause of poorly performing systems. A measured, room-by-room design avoids both problems and shows the reasoning behind every figure.

For Devon homes with extensions or loft conversions, each part of the house is assessed on its own construction. Design outdoor temperatures for Devon and the wider Devon come from local cold-weather data, not a national average. A surveyor visits your home to measure each room, window and wall before any heat pump is sized.

Who it suits

  • Homeowners planning insulation or building work who want to know the effect on heat demand
  • Landlords comparing properties before deciding where to switch first
  • Homes with an existing heat pump that seems undersized or expensive to run
  • Self-builders and architects who need emitter and system sizes early

Grants and rules for heat pumps in England

England

In England the Boiler Upgrade Scheme gives £7,500 towards an air source heat pump (£9,000 if it replaces oil or LPG, from 21 July 2026 to 31 March 2027), and since 28 April 2026 a valid EPC is no longer needed. The grant is applied for by the MCS-certified installer and shown as a deduction on your quote.

Installing heat pumps is zero-rated for VAT across the UK until 31 March 2027. Since 29 May 2025, permitted development in England allows up to two air source heat pumps on a house, each up to 1.5 m³, with no blanket 1 m boundary rule — the installation must still meet the MCS planning standards, including the noise check. Listed buildings, flats and some conservation-area positions need extra consent, which we check at survey.

Heat loss survey prices in Devon

Here are typical prices for heat loss surveys in Devon, installed and including VAT. Use the guide price tool for a figure based on your home, then a survey confirms it in writing.

Heat loss survey prices in Devon
SurveyGuide price
Home survey and heat loss calculation with an installation quoteFree
Stand-alone heat loss survey and report£150–£400

Inc VAT. A stand-alone report is for homeowners who want the design without an installation quote.

Towns we cover in Devon

We cover 18 towns in Devon for heat loss surveys. Each links to local guide prices and the grant position for England.

TownPostcode districtNearest townMidwinter daylight
PlymouthPL1Saltash8 h 01 min
ExeterEX4Crediton7 h 57 min
PaigntonTQ3Torquay8 h 00 min
TorquayTQ1Paignton8 h 00 min
Newton AbbotTQ12Torquay7 h 59 min
ExmouthEX8Sidmouth7 h 58 min
BarnstapleEX31Bideford7 h 54 min
BidefordEX39Barnstaple7 h 54 min
TivertonEX16Crediton7 h 56 min
CreditonEX17Exeter7 h 57 min
DartmouthTQ6Paignton8 h 01 min
HonitonEX14Sidmouth7 h 57 min
IlfracombeEX34Barnstaple7 h 52 min
KingsbridgeTQ7Dartmouth8 h 02 min
OkehamptonEX20Tavistock7 h 57 min
SidmouthEX10Honiton7 h 58 min
TavistockPL19Plymouth7 h 59 min
TotnesTQ9Paignton8 h 00 min

Heat loss surveys questions

Is the heat loss survey free?

Yes, for installation enquiries the home survey and heat loss calculation are free, and the results form the basis of your written quote. If you only want the calculation and report, for example for building plans or comparing quotes, a stand-alone heat loss survey has a guide price of £150–£400, including VAT. We confirm which applies when you book.

Can I use the heat loss report to get other quotes?

Yes. A stand-alone heat loss report is yours to use, including sharing it with other installers so their quotes are based on the same figures. Comparing quotes like for like makes it easier to see differences in equipment, radiator upgrades and workmanship terms. The report states the assumptions used wherever construction could not be confirmed.

Why can't you size the heat pump from my boiler?

Boilers are often much larger than a home's real heat loss, because they are sized for fast hot water and quick warm-ups. Matching a heat pump to the boiler's output usually means an oversized unit that costs more and switches on and off too often. A room-by-room calculation finds the actual heat demand, which is what the heat pump needs to meet.

How long does a heat loss survey take?

A typical survey takes 1–3 hours on site, depending on the size and complexity of the home. Larger or older houses with mixed construction, extensions or many rooms take longer. The calculations and design are completed afterwards, and the results are included in your quote or stand-alone report.

Ready to price your heat pump?

Use the guide price tool, or book a free home survey and fixed written quote.

CallGet a quote