Air source heat pumps, surveyed, designed and installed· Free home survey for installation enquiries
0800 088 6341
High-temperature heat pumps
England · 11 towns

High-temperature heat pumps in Leicestershire

We arrange air source heat pumps for homes throughout Leicestershire, from the first heat loss survey to commissioning and annual servicing.

A high-temperature heat pump is an air-to-water heat pump able to produce flow temperatures of around 65–75°C, close to what a gas or oil boiler delivers, instead of the 35–50°C at which standard heat pumps run most efficiently. That means existing radiators can often heat rooms much as they do now, without being replaced with larger ones.

Installers in Leicestershire set the weather compensation curve so the unit runs cooler on mild days. For older Leicestershire homes with microbore pipework, a higher flow temperature can avoid lifting floors to replace pipes. A survey in Leicestershire can compare a high-temperature unit with upsizing a few radiators, for homes anywhere in Leicestershire.

Who it suits

  • Homes with microbore pipework that would be disruptive to replace
  • Period and listed homes where the radiators are part of the character
  • Rooms with no wall space for a larger radiator
  • Older homes where insulation improvements are limited

Grants and rules for heat pumps in England

England

In England the Boiler Upgrade Scheme gives £7,500 towards an air source heat pump (£9,000 if it replaces oil or LPG, from 21 July 2026 to 31 March 2027), and since 28 April 2026 a valid EPC is no longer needed. The grant is applied for by the MCS-certified installer and shown as a deduction on your quote.

There is no VAT on installing a heat pump anywhere in the UK until 31 March 2027. In England most houses can have an air source heat pump under permitted development, provided the unit meets the MCS noise and siting standards; the old 1 m boundary limit was removed on 29 May 2025. We flag listed buildings, flats and sensitive conservation-area positions at survey.

High-temperature heat pumps prices in Leicestershire

Here are typical prices for high-temperature heat pumps in Leicestershire, installed and including VAT. Use the guide price tool for a figure based on your home, then a survey confirms it in writing.

High-temperature heat pumps prices in Leicestershire
HomeTypical sizeInstalled guide priceAfter £7,500 grant
1–2 bedroom flat or small terrace4–5 kW£9,500–£12,500£2,000–£5,000
2–3 bedroom terrace or semi5–7 kW£10,500–£13,500£3,000–£6,000
3 bedroom semi or small detached6–9 kW£12,000–£15,500£4,500–£8,000
4 bedroom detached8–12 kW£14,000–£18,000£6,500–£10,500
5+ bedroom or larger older house11–16 kW£16,500–£22,500£9,000–£15,000

Installed, inc VAT: unit, cylinder, controls, minor pipework and commissioning. A high-temperature unit typically adds £1,500–£3,000.

Towns we cover in Leicestershire

We cover 11 towns in Leicestershire for high-temperature heat pumps. Each links to local guide prices and the grant position for England.

TownPostcode districtNearest townMidwinter daylight
LeicesterLE1Oadby7 h 38 min
LoughboroughLE12Coalville7 h 36 min
HinckleyLE10Earl Shilton7 h 39 min
CoalvilleLE67Ashby-de-la-Zouch7 h 37 min
Wigston MagnaLE18Oadby7 h 38 min
Melton MowbrayLE13Oakham7 h 36 min
Market HarboroughLE16Desborough7 h 39 min
OadbyLE2Wigston Magna7 h 38 min
Earl ShiltonLE9Hinckley7 h 38 min
Ashby-de-la-ZouchLE65Coalville7 h 36 min
LutterworthLE17Rugby7 h 40 min

High-temperature heat pumps questions

Can a heat pump work with my existing radiators?

Often, yes, especially with a high-temperature unit. Standard heat pumps run most efficiently at 35–50°C, so some radiators may be too small at those temperatures. A high-temperature unit can run at around 65–75°C, so existing radiators can usually heat rooms much as they do with a boiler, at a cost in efficiency. The survey checks every radiator against its room's heat loss.

Do I still need a hot water cylinder?

Yes. Like other air-to-water heat pumps, a high-temperature unit heats a stored cylinder rather than supplying hot water on demand. Its higher output temperature can help the cylinder reach the temperature needed for its periodic legionella cycle with less reliance on the immersion heater. The cylinder is sized for your household at survey.

Are high-temperature heat pumps less efficient?

Yes, when they run hot. Every heat pump uses more electricity per unit of heat as the flow temperature rises, so a unit running at 70°C is less efficient than one running at 45°C. With weather compensation it runs cooler for much of the year, which narrows the gap. The design aims to keep the maximum temperature as low as your radiators allow.

Why do many high-temperature units use R290?

R290 is propane, a natural refrigerant with a very low global warming impact. Its properties make higher water temperatures more achievable than with some earlier refrigerants. Because it is flammable, manufacturers set clearance zones around the outdoor unit from windows, doors, drains and other openings, which the survey uses when choosing a position.

Ready to price your heat pump?

Use the guide price tool, or book a free home survey and fixed written quote.

CallGet a quote