Because the refrigerant circuit is sealed at the factory, the installer does not need to handle refrigerant on site in a typical installation, which keeps the job simpler. Inside, you still have a cylinder, controls and a small set of components for the water circuit, such as pumps, valves and an expansion vessel, but there is no indoor refrigerant unit to find wall space for.
Bungalows in Leicestershire often let the unit sit right beside the plant cupboard, keeping water pipes short. For Leicestershire terraces with small yards, the survey confirms the unit fits with the clearances it needs. In exposed spots around Leicestershire, frost protection for the outdoor pipework is chosen with the site in mind.
Who it suits
- Owners who want the simplest installation, with no indoor refrigerant
- Houses and bungalows with outdoor space close to where pipes enter the home
- Households that want to keep refrigerant work out of routine servicing
- Homes where the unit can sit within a short pipe run of the cylinder
Grants and rules for heat pumps in England
Homes in Leicestershire can use the Boiler Upgrade Scheme, which takes £7,500 off the cost of an air source heat pump when it replaces fossil-fuel or electric heating. Replacing oil or LPG heating qualifies for £9,000 for installations from 21 July 2026 to 31 March 2027, and air-to-air systems for £2,500. The MCS-certified installer named in your quote applies for the grant and deducts it from the price.
There is no VAT on installing a heat pump anywhere in the UK until 31 March 2027. In England most houses can have an air source heat pump under permitted development, provided the unit meets the MCS noise and siting standards; the old 1 m boundary limit was removed on 29 May 2025. We flag listed buildings, flats and sensitive conservation-area positions at survey.
Monobloc heat pumps prices in Leicestershire
Here are typical prices for monobloc heat pumps in Leicestershire, installed and including VAT. Use the guide price tool for a figure based on your home, then a survey confirms it in writing.
| Home | Typical size | Installed guide price | After £7,500 grant |
|---|---|---|---|
| 1–2 bedroom flat or small terrace | 4–5 kW | £9,500–£12,500 | £2,000–£5,000 |
| 2–3 bedroom terrace or semi | 5–7 kW | £10,500–£13,500 | £3,000–£6,000 |
| 3 bedroom semi or small detached | 6–9 kW | £12,000–£15,500 | £4,500–£8,000 |
| 4 bedroom detached | 8–12 kW | £14,000–£18,000 | £6,500–£10,500 |
| 5+ bedroom or larger older house | 11–16 kW | £16,500–£22,500 | £9,000–£15,000 |
Installed, inc VAT: unit, cylinder, controls, minor pipework and commissioning.
Towns we cover in Leicestershire
We cover 11 towns in Leicestershire for monobloc heat pumps. Each links to local guide prices and the grant position for England.
| Town | Postcode district | Nearest town | Midwinter daylight |
|---|---|---|---|
| Leicester | LE1 | Oadby | 7 h 38 min |
| Loughborough | LE12 | Coalville | 7 h 36 min |
| Hinckley | LE10 | Earl Shilton | 7 h 39 min |
| Coalville | LE67 | Ashby-de-la-Zouch | 7 h 37 min |
| Wigston Magna | LE18 | Oadby | 7 h 38 min |
| Melton Mowbray | LE13 | Oakham | 7 h 36 min |
| Market Harborough | LE16 | Desborough | 7 h 39 min |
| Oadby | LE2 | Wigston Magna | 7 h 38 min |
| Earl Shilton | LE9 | Hinckley | 7 h 38 min |
| Ashby-de-la-Zouch | LE65 | Coalville | 7 h 36 min |
| Lutterworth | LE17 | Rugby | 7 h 40 min |
Monobloc heat pumps questions
What refrigerant do monobloc heat pumps use?
Most use R32 or R290. R290 is propane, a natural refrigerant with a very low global warming impact, and some models use it to reach higher flow temperatures. Because R290 is flammable, manufacturers set clearance zones around the unit from openings such as windows, doors and drains, which the survey takes into account when choosing a position.
Are monobloc heat pumps covered by grants?
Yes. Monobloc units are air-to-water heat pumps, so in England and Wales they are covered by the Boiler Upgrade Scheme grant of £7,500 for eligible homes, or £9,000 when replacing oil or LPG heating within the published dates. In Scotland, Home Energy Scotland funding requires an MCS-certified installer and products. There is no dedicated homeowner heat pump grant in Northern Ireland at present.
How far can a monobloc unit be from the house?
Usually as close as practical, because water pipes outside lose heat and need frost protection. Manufacturers set limits on pipe length and size, and longer runs need larger, better-insulated pipes. Most homes site the unit against or near an outside wall close to where the pipes enter. If the only good position is far from the house, a split system may suit better.
What is the difference between monobloc and split heat pumps?
A monobloc unit holds all of its refrigerant in the outdoor unit and sends heated water into the house. A split system has an outdoor unit and an indoor unit called a hydrobox, connected by refrigerant pipes, with heat passed to water indoors. Monobloc installs are simpler; splits avoid outdoor water pipes but need an F-gas certified engineer for the refrigerant work. Our monobloc vs split guide compares them.