Air source heat pumps, surveyed, designed and installed· Free home survey for installation enquiries
0800 088 6341
High-temperature heat pumps
England · 7 towns

High-temperature heat pumps in Shropshire

We arrange air source heat pumps for homes throughout Shropshire, from the first heat loss survey to commissioning and annual servicing.

The trade-off is efficiency. The hotter the water a heat pump makes, the more electricity it needs for each unit of heat, so a system running at 65°C has a lower seasonal efficiency than one running at 45°C. Good design still matters: weather compensation runs the unit cooler on mild days and only raises the temperature in the coldest weather, which keeps running costs down across the year.

A survey in Shropshire can compare a high-temperature unit with upsizing a few radiators, for homes anywhere in Shropshire. For older Shropshire homes with microbore pipework, a higher flow temperature can avoid lifting floors to replace pipes. Older homes around Shropshire often need a discreet unit position, such as a rear courtyard, which the survey looks for first.

Who it suits

  • Period and listed homes where the radiators are part of the character
  • Rooms with no wall space for a larger radiator
  • Older homes where insulation improvements are limited
  • Homes with microbore pipework that would be disruptive to replace

Grants and rules for heat pumps in England

England

Homes in Shropshire can use the Boiler Upgrade Scheme, which takes £7,500 off the cost of an air source heat pump when it replaces fossil-fuel or electric heating. Replacing oil or LPG heating qualifies for £9,000 for installations from 21 July 2026 to 31 March 2027, and air-to-air systems for £2,500. The MCS-certified installer named in your quote applies for the grant and deducts it from the price.

Installing heat pumps is zero-rated for VAT across the UK until 31 March 2027. Since 29 May 2025, permitted development in England allows up to two air source heat pumps on a house, each up to 1.5 m³, with no blanket 1 m boundary rule — the installation must still meet the MCS planning standards, including the noise check. Listed buildings, flats and some conservation-area positions need extra consent, which we check at survey.

High-temperature heat pumps prices in Shropshire

Here are typical prices for high-temperature heat pumps in Shropshire, installed and including VAT. Use the guide price tool for a figure based on your home, then a survey confirms it in writing.

High-temperature heat pumps prices in Shropshire
HomeTypical sizeInstalled guide priceAfter £7,500 grant
1–2 bedroom flat or small terrace4–5 kW£9,500–£12,500£2,000–£5,000
2–3 bedroom terrace or semi5–7 kW£10,500–£13,500£3,000–£6,000
3 bedroom semi or small detached6–9 kW£12,000–£15,500£4,500–£8,000
4 bedroom detached8–12 kW£14,000–£18,000£6,500–£10,500
5+ bedroom or larger older house11–16 kW£16,500–£22,500£9,000–£15,000

Installed, inc VAT: unit, cylinder, controls, minor pipework and commissioning. A high-temperature unit typically adds £1,500–£3,000.

Towns we cover in Shropshire

We cover 7 towns in Shropshire for high-temperature heat pumps. Each links to local guide prices and the grant position for England.

TownPostcode districtNearest townMidwinter daylight
TelfordTF4Bridgnorth7 h 37 min
ShrewsburySY1Church Stretton7 h 37 min
OswestrySY11Shrewsbury7 h 35 min
BridgnorthWV15Telford7 h 39 min
Church StrettonSY6Ludlow7 h 39 min
LudlowSY8Tenbury Wells7 h 40 min
Market DraytonTF9Nantwich7 h 35 min

High-temperature heat pumps questions

Do I still need a hot water cylinder?

Yes. Like other air-to-water heat pumps, a high-temperature unit heats a stored cylinder rather than supplying hot water on demand. Its higher output temperature can help the cylinder reach the temperature needed for its periodic legionella cycle with less reliance on the immersion heater. The cylinder is sized for your household at survey.

Are high-temperature heat pumps less efficient?

Yes, when they run hot. Every heat pump uses more electricity per unit of heat as the flow temperature rises, so a unit running at 70°C is less efficient than one running at 45°C. With weather compensation it runs cooler for much of the year, which narrows the gap. The design aims to keep the maximum temperature as low as your radiators allow.

Can a heat pump work with my existing radiators?

Often, yes, especially with a high-temperature unit. Standard heat pumps run most efficiently at 35–50°C, so some radiators may be too small at those temperatures. A high-temperature unit can run at around 65–75°C, so existing radiators can usually heat rooms much as they do with a boiler, at a cost in efficiency. The survey checks every radiator against its room's heat loss.

Is a high-temperature heat pump right for a listed building?

It can be, because it reduces the need to replace period radiators or lift historic floors for new pipework. The outdoor unit position still matters: in England, listed buildings need listed building consent for external works, and the other nations have their own rules. We check what applies at survey and look for discreet positions, such as a rear courtyard or behind an outbuilding.

Ready to price your heat pump?

Use the guide price tool, or book a free home survey and fixed written quote.

CallGet a quote