Air source heat pumps, surveyed, designed and installed· Free home survey for installation enquiries
0800 088 6341
Heat loss survey
England · 14 towns

Heat loss survey in Merseyside

Switching to a heat pump in Merseyside? Start with a guide price, then a surveyor measures your home and the written quote fixes the price.

Getting the size right matters. An undersized heat pump struggles in cold weather, while an oversized one costs more to buy and can switch on and off frequently, which wastes energy and wears components. Sizing from a rule of thumb, or simply matching the old boiler's output, is a common cause of poorly performing systems. A measured, room-by-room design avoids both problems and shows the reasoning behind every figure.

Homeowners in Merseyside thinking about insulation work can use the survey to see how it would change their heat pump size. A surveyor visits your home to measure each room, window and wall before any heat pump is sized. The survey in Merseyside includes a check of where the outdoor unit could sit and how its sound would reach neighbours.

Who it suits

  • Anyone getting a heat pump quote, as the first step
  • Homes with an existing heat pump that seems undersized or expensive to run
  • Self-builders and architects who need emitter and system sizes early
  • Landlords comparing properties before deciding where to switch first

Grants and rules for heat pumps in England

England

Homes in Merseyside can use the Boiler Upgrade Scheme, which takes £7,500 off the cost of an air source heat pump when it replaces fossil-fuel or electric heating. Replacing oil or LPG heating qualifies for £9,000 for installations from 21 July 2026 to 31 March 2027, and air-to-air systems for £2,500. The MCS-certified installer named in your quote applies for the grant and deducts it from the price.

There is no VAT on installing a heat pump anywhere in the UK until 31 March 2027. In England most houses can have an air source heat pump under permitted development, provided the unit meets the MCS noise and siting standards; the old 1 m boundary limit was removed on 29 May 2025. We flag listed buildings, flats and sensitive conservation-area positions at survey.

Heat loss survey prices in Merseyside

The ranges below are typical installed prices for homes in Merseyside, including VAT. A survey sets the exact figure, because two similar-looking houses in Merseyside can need quite different radiators and pipework.

Heat loss survey prices in Merseyside
SurveyGuide price
Home survey and heat loss calculation with an installation quoteFree
Stand-alone heat loss survey and report£150–£390

Inc VAT. A stand-alone report is for homeowners who want the design without an installation quote.

Towns we cover in Merseyside

We cover 14 towns in Merseyside for heat loss surveys. Each links to local guide prices and the grant position for England.

TownPostcode districtNearest townMidwinter daylight
LiverpoolL3Birkenhead7 h 29 min
BirkenheadCH41Liverpool7 h 29 min
St HelensWA10Prescot7 h 29 min
SouthportPR8Formby7 h 26 min
WallaseyCH45Birkenhead7 h 29 min
BootleL21Wallasey7 h 28 min
BebingtonCH63Birkenhead7 h 30 min
HuytonL36Prescot7 h 29 min
KirkbyL32Maghull7 h 28 min
PrescotL34Huyton7 h 29 min
HeswallCH60Bebington7 h 30 min
MaghullL31Kirkby7 h 28 min
FormbyL37Maghull7 h 27 min
HalewoodL26Huyton7 h 30 min

Heat loss surveys questions

Why can't you size the heat pump from my boiler?

Boilers are often much larger than a home's real heat loss, because they are sized for fast hot water and quick warm-ups. Matching a heat pump to the boiler's output usually means an oversized unit that costs more and switches on and off too often. A room-by-room calculation finds the actual heat demand, which is what the heat pump needs to meet.

How long does a heat loss survey take?

A typical survey takes 1–3 hours on site, depending on the size and complexity of the home. Larger or older houses with mixed construction, extensions or many rooms take longer. The calculations and design are completed afterwards, and the results are included in your quote or stand-alone report.

Can I use the heat loss report to get other quotes?

Yes. A stand-alone heat loss report is yours to use, including sharing it with other installers so their quotes are based on the same figures. Comparing quotes like for like makes it easier to see differences in equipment, radiator upgrades and workmanship terms. The report states the assumptions used wherever construction could not be confirmed.

What is a design flow temperature?

The design flow temperature is the temperature of the water sent to your radiators or underfloor heating on the coldest design day. Heat pumps are more efficient at lower flow temperatures, typically around 35–50°C. Choosing it is a balance: a lower figure improves efficiency but can mean larger radiators in some rooms, so the design shows both.

Ready to price your heat pump?

Use the guide price tool, or book a free home survey and fixed written quote.