We arrange air source heat pumps for homes throughout Cheshire, from the first heat loss survey to commissioning and annual servicing.

Getting the size right matters. An undersized heat pump struggles in cold weather, while an oversized one costs more to buy and can switch on and off frequently, which wastes energy and wears components. Sizing from a rule of thumb, or simply matching the old boiler's output, is a common cause of poorly performing systems. A measured, room-by-room design avoids both problems and shows the reasoning behind every figure.

A surveyor visits your home to measure each room, window and wall before any heat pump is sized. For Cheshire homes with extensions or loft conversions, each part of the house is assessed on its own construction. The survey in Cheshire includes a check of where the outdoor unit could sit and how its sound would reach neighbours.

Who it suits

  • Anyone getting a heat pump quote, as the first step
  • Landlords comparing properties before deciding where to switch first
  • Homes with an existing heat pump that seems undersized or expensive to run
  • Self-builders and architects who need emitter and system sizes early

Grants and rules for heat pumps in England

England

In England the Boiler Upgrade Scheme gives £7,500 towards an air source heat pump (£9,000 if it replaces oil or LPG, from 21 July 2026 to 31 March 2027), and since 28 April 2026 a valid EPC is no longer needed. The grant is applied for by the MCS-certified installer and shown as a deduction on your quote.

Installing heat pumps is zero-rated for VAT across the UK until 31 March 2027. Since 29 May 2025, permitted development in England allows up to two air source heat pumps on a house, each up to 1.5 m³, with no blanket 1 m boundary rule — the installation must still meet the MCS planning standards, including the noise check. Listed buildings, flats and some conservation-area positions need extra consent, which we check at survey.

Heat loss survey prices in Cheshire

Here are typical prices for heat loss surveys in Cheshire, installed and including VAT. Use the guide price tool for a figure based on your home, then a survey confirms it in writing.

Heat loss survey prices in Cheshire
SurveyGuide price
Home survey and heat loss calculation with an installation quoteFree
Stand-alone heat loss survey and report£150–£400

Inc VAT. A stand-alone report is for homeowners who want the design without an installation quote.

Towns we cover in Cheshire

We cover 18 towns in Cheshire for heat loss surveys. Each links to local guide prices and the grant position for England.

TownPostcode districtNearest townMidwinter daylight
WarringtonWA1Widnes7 h 29 min
ChesterCH1Ellesmere Port7 h 31 min
CreweCW1Nantwich7 h 33 min
Ellesmere PortCH65Chester7 h 30 min
WidnesWA8Runcorn7 h 30 min
RuncornWA7Widnes7 h 30 min
MacclesfieldSK11Alderley Edge7 h 31 min
NorthwichCW9Winsford7 h 31 min
WinsfordCW7Middlewich7 h 31 min
CongletonCW12Sandbach7 h 32 min
WilmslowSK9Alderley Edge7 h 30 min
SandbachCW11Crewe7 h 32 min
NantwichCW5Crewe7 h 33 min
Alderley EdgeSK9Wilmslow7 h 30 min
FrodshamWA6Runcorn7 h 30 min
KnutsfordWA16Alderley Edge7 h 30 min
MiddlewichCW10Winsford7 h 31 min
TarporleyCW6Winsford7 h 32 min

Heat loss surveys questions

How long does a heat loss survey take?

A typical survey takes 1–3 hours on site, depending on the size and complexity of the home. Larger or older houses with mixed construction, extensions or many rooms take longer. The calculations and design are completed afterwards, and the results are included in your quote or stand-alone report.

What is a design flow temperature?

The design flow temperature is the temperature of the water sent to your radiators or underfloor heating on the coldest design day. Heat pumps are more efficient at lower flow temperatures, typically around 35–50°C. Choosing it is a balance: a lower figure improves efficiency but can mean larger radiators in some rooms, so the design shows both.

Can I use the heat loss report to get other quotes?

Yes. A stand-alone heat loss report is yours to use, including sharing it with other installers so their quotes are based on the same figures. Comparing quotes like for like makes it easier to see differences in equipment, radiator upgrades and workmanship terms. The report states the assumptions used wherever construction could not be confirmed.

Will the survey check noise from the outdoor unit?

Yes. The surveyor identifies possible positions for the outdoor unit and carries out the MCS noise assessment, which estimates the sound level at the nearest neighbouring window from the unit's sound power level, distance and any barriers. In England, meeting the MCS planning standards is one of the conditions for permitted development. Wales, Scotland and Northern Ireland have their own rules, which we check.

Ready to price your heat pump?

Use the guide price tool, or book a free home survey and fixed written quote.

CallGet a quote