Heat pump controls are the settings and devices that decide how warm the water in your heating is, when the heat pump runs and when it heats hot water. The most important is weather compensation, which raises the flow temperature gradually as it gets colder outside and lowers it in milder weather, so the system only ever runs as warm as it needs to.
Hot water schedules in Lanarkshire can be timed to suit shift work, school runs or working from home. Homeowners in Lanarkshire get a walkthrough of their controls at handover, with a simple written guide to keep. For Lanarkshire homes with extensions, we plan zones so the new space heats properly without making the heat pump cycle.
Who it suits
- Every new heat pump installation, set up at commissioning
- Households considering a heat pump or time-of-use electricity tariff
- Existing heat pumps that feel expensive to run or slow to respond
- Homes with solar PV or a battery that want hot water timed to match
Grants and rules for heat pumps in Scotland
The Boiler Upgrade Scheme does not apply in Scotland. Instead, homeowners in Lanarkshire can apply to Home Energy Scotland for a grant of up to £7,500 towards a heat pump, with up to £1,500 more for eligible rural and island homes, plus an optional interest-free loan of up to £7,500. You need a written funding offer before any work starts.
There is no VAT on installing a heat pump anywhere in the UK, Scotland included, until 31 March 2027. Scottish permitted development rules and building standards apply, and the surveyor checks the unit position and any listed or conservation-area constraints.
Prices
Weather-compensating controls and set-up are included in every full system price. See the guide prices for full systems.
Towns we cover in Lanarkshire
We cover 13 towns in Lanarkshire for heat pump controls and tariffs. Each links to local guide prices and the grant position for Scotland.
| Town | Postcode district | Nearest town | Midwinter daylight |
|---|---|---|---|
| East Kilbride | G74 | Cambuslang | 7 h 00 min |
| Hamilton | ML3 | Motherwell | 7 h 00 min |
| Cumbernauld | G67 | Airdrie | 6 h 57 min |
| Coatbridge | ML5 | Airdrie | 6 h 59 min |
| Airdrie | ML6 | Coatbridge | 6 h 59 min |
| Motherwell | ML1 | Bellshill | 7 h 00 min |
| Rutherglen | G73 | Cambuslang | 6 h 59 min |
| Cambuslang | G73 | Rutherglen | 6 h 59 min |
| Wishaw | ML2 | Motherwell | 7 h 00 min |
| Bellshill | ML4 | Motherwell | 6 h 59 min |
| Carluke | ML8 | Wishaw | 7 h 00 min |
| Lanark | ML11 | Carluke | 7 h 01 min |
| Strathaven | ML10 | Hamilton | 7 h 01 min |
Heat pump controls and tariffs questions
Is a heat pump tariff a good idea?
A heat pump or time-of-use tariff can lower running costs if your household can shift hot water heating and some space heating into the cheaper periods. Whether it suits you depends on the rates, the standing charge, your routine and whether you have a battery. Compare the total expected cost on your own usage, not only the headline rate.
How should I set the hot water on a heat pump?
Most households heat hot water once or twice a day at set times rather than on demand. Timing the main heat for a cheaper tariff period, or for the middle of the day when solar panels generate, helps keep costs down. A weekly legionella cycle raises the water temperature higher, and we schedule it at a sensible time.
Should I turn my heat pump off at night?
Usually not. Switching off lets the house cool, and the heat pump then has to run at a higher flow temperature to recover, which lowers efficiency. A small set-back of 1–2°C overnight is generally more economical. Homes with very good insulation or a time-of-use tariff may suit different patterns, which we can set up.
What flow temperature should my heat pump run at?
It depends on the design: the flow temperature is set so your radiators or underfloor heating can heat each room on a cold day. Well-designed systems typically run at around 35–50°C at their coldest, and lower in milder weather through weather compensation. Your design paperwork states the design flow temperature, and we set the heating curve to match it.